e
Supply Voltage/Control Voltage/Frequency/CPT Selection
Frame
Size
Voltage
Frequency
(Hz)
Code
Nominal
Line
Control
With a
C.P.T
(1)
(1) A Control Power Transformer modification must be selected (6, 6B, and so on) to size the
transformer.
Without a
C.P.T
(2)
(2) Control Circuit Power is supplied from separate/external source.
“A” Frame
2400
120
60
A AD
120…240 AA —
3300
110
50
CY CDY
220 CP
CDP
4160
110
50
EY
EDY
220 EP
EDP
120
60
E ED
120…240 EA —
6600
110
50
JY
JDY
220 JP
JDP
110…220 JAY —
120
60
J JD
240 JA
—
“B” and “C”
Frames
(3)
(3) Three-phase Control Circuit Power is supplied from separate/external source.
2400
208
60
AHD
480 ABD
600 ACD
3300
230
50
CPD
380 CND
400 CKD
4160
230
50
EPD
380 END
400 EKD
208
60
EHD
480 EBD
600 ECD
6600
230
50
JPD
380 JND
400 JKD
208
60
JHD
480 JBD
600 JCD
f
Rectifier Configuration/Line Impedance Type
Code Description
RPDTD
AFE Rectifier with Integral Line Reactor and
Direct-to-Drive™ DC Link
RPTX
AFE Rectifier with provision for connection to separate
Isolation Transformer (standard DC Link)
RPTXI
AFE Rectifier with integral Isolation Transformer
(standard DC Link)
(1)
(1) RPTXI configuration is only available for “A” Frame configurations.
R18TX
18-pulse Rectifier with provision for connection to separate
Isolation Transformer (standard DC Link)
(2)
(2) R18TX configuration is only available for “B” and “C” Frame configurations.
Position
1234567
7000 A 40 D A RPDTD 1–…etc.
abcdef