a
Bulletin Number
Code Description
7000A “A” Frame (Air-cooled)
7000 “B” Frame (Air-cooled)
7000L “C” Frame (Liquid-cooled)
b
Service Duty/Altitude Code
Code Description
A Normal Duty, 0…1000 m Altitude. Maximum 40 °C Ambient
B
Normal Duty, 1001…5000 m Altitude
Reduced Ambient (from 40 °C offering)
1001…2000 m = 37.5 °C
2001…3000 m = 35 °C
3001…4000 m = 32.5 °C
4001…5000 m = 30 °C
C Heavy Duty, 0…1000 m Altitude. Maximum 40 °C Ambient
D
Heavy Duty, 1001…5000 m Altitude. Reduced Ambient
(from 40 °C offering) – same as “B” code above
E Normal Duty, 0…1000 m Altitude. Maximum 35 °C Ambient
F
Normal Duty, 1001…5000 m Altitude
Reduced Ambient (from 35 °C offering)
1001…2000 m = 32.5 °C
2001…3000 m = 30 °C
3001…4000 m = 27.5 °C
4001…5000 m = 25 °C
G Heavy Duty, 0…1000 m Altitude. Maximum 35 °C Ambient
J Normal Duty, 0…1000 m Altitude. Maximum 50 °C Ambient
L Heavy Duty, 0…1000 m Altitude. Maximum 50 °C Ambient
N Normal Duty, 0…1000 m Altitude. Maximum 20 °C Ambient
Z Custom Configuration (Contact Factory)
c
Drive Current Rating
(1)
(1) Not all amperages are available at all ambient/altitude configurations.
Code Description Code Description
40 40 A 215 215 A
46 46 A 250 250 A
53 53 A 285 285 A
61 61 A 325 325 A
70 70 A 375 375 A
81 81 A 430 430 A
93 93 A 495 495 A
105 105 A 575 575 A
120 120 A 625 625 A
140 140 A 657 657 A
160 160 A 720 720 A
185 185 A
d
Enclosure Type
Code Description
D Type 1 w/gasket (IP21)
T Type 1 w/gasket (IP21) – Seismic rated
KIP42
U IP42 – Seismic rated
Position
1234567
7000 A 40 D A RPDTD 1–…etc.