The Operator Panel
Operator's Handbook, Autroprime Interactive Fire Detection System, 116-P-APRIME-OPERATE/FGB Rev. B, 2009-10-28,
Autronica Fire and Security AS
Page 8
2.2 Indicators
2.2.1 Upper Section
Pre Alarm One or more detection zones are in the pre-alarm state.
Remote Call Steady red light when the message is sent to a remote device, for
example, the Fire Brigade.
Remote Call Response Steady red light when an acknowledge message is received from the
remote device, for example, the Fire Brigade.
Fault The presence of a fault.
 Pulsing light
Unacknowledged fault warnings exist
 Steady light
All fault warnings have been acknowledged
Disabled Function
Steady yellow light when one or more of the following components
are in the disabled state:
 detection zones and alarm zones
 individual points
 outputs and inputs
 Fire Alarm Devices, Fire Alarm Routing Equipment, Fire
Protection Equipment and Fault Warning Routing Equipment.
Test Condition Steady yellow light when one or more of the following components
have been manually set to the test condition:
 detection zones and alarm zones
 fire alarm devices
 outputs
Supervisory Condition The presence of an input device (for example, door control units,
monitor and control units) that is in the supervisory state.
 A pulsing light
Unacknowledged points in Supervisory state exist
 Steady light
All points in Supervisory state have been acknowledged
System Fault Steady yellow light when a system fault is present.
Power Steady green light when power is ON.
The circular red alarm indicator
shows that one or more detection
zones are in the fire alarm state.
 Pulsing red light:
In the event of a fire alarm. The Fire Alarm
Devices (FAD), (if any), are still in active
state.
 Steady red light:
All FADs activated by the fire alarm
condition have been deactivated by
operating the Silence Alarms button. The
control and indicating equipment still
remain in the fire alarm condition.
In the event of more than one alarm. The red
More Events indicator shows that several
detection zones are in the fire alarm state.

Table of Contents

Other manuals for Autronica Autroprime

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Autronica Autroprime and is the answer not in the manual?

Autronica Autroprime Specifications

General IconGeneral
BrandAutronica
ModelAutroprime
CategoryFire Alarms
LanguageEnglish

Related product manuals