Operation Mode
Operator's Handbook, AutroSafe Interactive Fire Alarm System, Release 3, ASAFE-FO/FE Rev. E, 021105,
Autronica Fire and Security AS
Page 29
3.16.6 Solas Detection Zones
When the operator panel receives a fire alarm signal from a point in a
SOLAS - Safety of Life at Sea - detection zone (configurable), all
actions will be initiated after a programmed delay has expired.
The (T1) delay period is started when a signal from a point is received.
Pressing Action digit 4, which represents BLOCK ALARM, will
terminate the delay period and block the alarm for an indefinite period
of time.
SOLAS applies to fire Alarm Devices (FAD), Fire Alarm Routing
Equipment (FARE) - detectors only, and Fire Protection Equipment
(FPE) - option.