EasyManuals Logo
Home>Casio>Calculator>FX-CG20 AU

Casio FX-CG20 AU User Manual

Casio FX-CG20 AU
608 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #568 background imageLoading...
Page #568 background image
ε-12
Using Advanced Setup
Note that the mode you select also determines the channel(s) you can use.
Sampling Mode Selectable Channel(s)
Real-time, Extended, Normal CH1, CH2, CH3, SONIC
Fast CH1, Mic
Sound Mic
Clock, Period CH1
3. To change the sampling interval setting, move the highlighting to “Interval”. Next, press
1 to display a dialog box for specifying the sampling interval.
The range of values you can select depends on the current sampling mode setting.
If this sampling mode is selected: This is the allowable setting range:
Real-time 0.2 to 299 sec
Fast 20 to 500 μsec
Extended 5 to 240 min
Period “=Trigger” only (no value input required)
Sound 20 to 27 μsec
Clock “=Trigger” only (no value input required)
Normal 0.0005 to 299 sec
4. To change the number of samples setting, move the highlighting to “Number”. Next, press
1 to display a dialog box for specifying the number of samples.
The total sampling time shown at the bottom of the dialog box is calculated by
multiplying the “Sampling Interval” value you specified in step 3 by the number of
samples you specify here.
Important!
When all of the following conditions exist, a “Distance” setting appears in place of the
“Number” setting. See “To configure the Distance setting” (page
ε-13) for information
about configuring the “Distance” setting.
- Channel setup (page
ε-9): 2(VERNIR) - [Photogate] - [Pulley], 3(CMA) -
[Photogate] - [Pulley]
- Sampling mode (page ε-11): Clock
5. To change the warm-up time setting, move the highlighting to “Warm-up”. Next, perform
one of the function key operations described below.
Note
The “Warm-up” setting will not be displayed on the Sample Setup screen if “Fast”,
“Sound” or “Extended” is currently selected as the sampling mode.
To do this: Press this key:
Have the warm-up time for each sensor set automatically
1(Auto)
Input a warm-up time, in seconds, manually
2(Manual)
Disable the warm-up time
3(None)