Functions 3 and 4 examples
Pressure by RPM control via J1939
Pressure by RPM control via analog output
Pressure by RPM control via J1939
Actual pressure is measured via Analog input, compared with Requested value and the 3-PI output
controls the engine RPM via J1939.
Input Analog input
Binary input: Request 2 (optional)
Binary input: R Reg Disable (optional)
Output Analog output: Speed Request
Setpoints
Regulator: Reg Input
Reg Bias
Request
Request 2
Reg Gain
Reg Integral
Engine params: MinSpeedLim
MaxSpeedLim
SpeedRamp
Take care if the Speed request in AUT mode is not limited by Engine params: Speed ramp.
Pressure by RPM control via Analog output
Actual pressure is measured via Analog input, compared with Requested value and the 3-PI output
controls the engine RPM via Analog output.