5.1.3 1-** Load / Motor
Paramet
er
number
Parameter description Default value 4-set-up Change
during
operation
Conver-
sion index
Type
1-0* General Settings
1-00 Conguration Mode ExpressionLimit All set-ups TRUE - Uint8
1-03 Torque Characteristics [3] Auto Energy Optim. VT All set-ups TRUE - Uint8
1-06 Clockwise Direction [0] Normal All set-ups FALSE - Uint8
1-1* Motor Selection
1-10 Motor Construction [0] Asynchron All set-ups FALSE - Uint8
1-1* VVC+ PM/SYN RM
1-14 Damping Gain 120 % All set-ups TRUE 0 Int16
1-15 Low Speed Filter Time Const. ExpressionLimit All set-ups TRUE -2 Uint16
1-16 High Speed Filter Time Const. ExpressionLimit All set-ups TRUE -2 Uint16
1-17 Voltage lter time const. ExpressionLimit All set-ups TRUE -3 Uint16
1-2* Motor Data
1-20 Motor Power [kW] ExpressionLimit All set-ups FALSE 1 Uint32
1-21 Motor Power [HP] ExpressionLimit All set-ups FALSE -2 Uint32
1-22 Motor Voltage ExpressionLimit All set-ups FALSE 0 Uint16
1-23 Motor Frequency ExpressionLimit All set-ups FALSE 0 Uint16
1-24 Motor Current ExpressionLimit All set-ups FALSE -2 Uint32
1-25 Motor Nominal Speed ExpressionLimit All set-ups FALSE 67 Uint16
1-26 Motor Cont. Rated Torque ExpressionLimit All set-ups FALSE -1 Uint32
1-28 Motor Rotation Check [0] O All set-ups FALSE - Uint8
1-29 Automatic Motor Adaptation (AMA) [0] O All set-ups FALSE - Uint8
1-3* Adv. Motor Data
1-30 Stator Resistance (Rs) ExpressionLimit All set-ups FALSE -4 Uint32
1-31 Rotor Resistance (Rr) ExpressionLimit All set-ups FALSE -4 Uint32
1-35 Main Reactance (Xh) ExpressionLimit All set-ups FALSE -4 Uint32
1-36 Iron Loss Resistance (Rfe) ExpressionLimit All set-ups FALSE -3 Uint32
1-37 d-axis Inductance (Ld) ExpressionLimit All set-ups FALSE -6 Int32
1-38 q-axis Inductance (Lq) ExpressionLimit All set-ups FALSE -6 Int32
1-39 Motor Poles ExpressionLimit All set-ups FALSE 0 Uint8
1-40 Back EMF at 1000 RPM ExpressionLimit All set-ups FALSE 0 Uint16
1-44 d-axis Inductance Sat. (LdSat) ExpressionLimit All set-ups FALSE -6 Int32
1-45 q-axis Inductance Sat. (LqSat) ExpressionLimit All set-ups FALSE -6 Int32
1-46 Position Detection Gain 120 % All set-ups TRUE 0 Uint16
1-47 Torque Calibration ExpressionLimit All set-ups TRUE - Uint8
1-48 Inductance Sat. Point ExpressionLimit All set-ups TRUE 0 Int16
1-49 q-axis Inductance Sat. Point ExpressionLimit All set-ups FALSE 0 Uint16
1-5* Load Indep. Setting
1-50 Motor Magnetisation at Zero Speed 100 % All set-ups TRUE 0 Uint16
1-51 Min Speed Normal Magnetising [RPM] ExpressionLimit All set-ups TRUE 67 Uint16
1-52 Min Speed Normal Magnetising [Hz] ExpressionLimit All set-ups TRUE -1 Uint16
1-58 Flying Start Test Pulses Current ExpressionLimit All set-ups FALSE 0 Uint16
1-59 Flying Start Test Pulses Frequency ExpressionLimit All set-ups FALSE 0 Uint16
1-6* Load Depen. Setting
1-60 Low Speed Load Compensation 100 % All set-ups TRUE 0 Int16
1-61 High Speed Load Compensation 100 % All set-ups TRUE 0 Int16
1-62 Slip Compensation 0 % All set-ups TRUE 0 Int16
1-63 Slip Compensation Time Constant ExpressionLimit All set-ups TRUE -2 Uint16
1-64 Resonance Dampening ExpressionLimit All set-ups TRUE 0 Uint16
1-65 Resonance Dampening Time Constant 5 ms All set-ups TRUE -3 Uint8
1-66 Min. Current at Low Speed ExpressionLimit All set-ups TRUE 0 Uint8
1-7* Start Adjustments
1-70 Start Mode [1] Parking All set-ups TRUE - Uint8
1-71 Start Delay 00 s All set-ups TRUE -1 Uint16
1-72 Start Function ExpressionLimit All set-ups TRUE - Uint8
1-73 Flying Start ExpressionLimit All set-ups TRUE - Uint8
1-77 Compressor Start Max Speed [RPM] ExpressionLimit All set-ups TRUE 67 Uint16
1-78 Compressor Start Max Speed [Hz] ExpressionLimit All set-ups TRUE -1 Uint16
1-79 Compressor Start Max Time to Trip 5 s All set-ups TRUE -1 Uint8
1-8* Stop Adjustments
1-80 Function at Stop [0] Coast All set-ups TRUE - Uint8
1-81 Min Speed for Function at Stop [RPM] ExpressionLimit All set-ups TRUE 67 Uint16
1-82 Min Speed for Function at Stop [Hz] ExpressionLimit All set-ups TRUE -1 Uint16
1-86 Trip Speed Low [RPM] ExpressionLimit All set-ups TRUE 67 Uint16
1-87 Trip Speed Low [Hz] ExpressionLimit All set-ups TRUE -1 Uint16
Parameter Lists Programming Guide
M0010001 Danfoss A/S © 10/2019 All rights reserved. 293
5 5

Table of Contents

Other manuals for Danfoss vlt FC 102

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss vlt FC 102 and is the answer not in the manual?

Danfoss vlt FC 102 Specifications

General IconGeneral
BrandDanfoss
Modelvlt FC 102
CategoryDC Drives
LanguageEnglish

Related product manuals