5.1.3 1-** Load / Motor
Paramet
er
number
Parameter description Default value 4-set-up Change
during
operation
Conver-
sion index
Type
1-0* General Settings
1-00 Conguration Mode ExpressionLimit All set-ups TRUE - Uint8
1-03 Torque Characteristics [3] Auto Energy Optim. VT All set-ups TRUE - Uint8
1-06 Clockwise Direction [0] Normal All set-ups FALSE - Uint8
1-1* Motor Selection
1-10 Motor Construction [0] Asynchron All set-ups FALSE - Uint8
1-1* VVC+ PM/SYN RM
1-14 Damping Gain 120 % All set-ups TRUE 0 Int16
1-15 Low Speed Filter Time Const. ExpressionLimit All set-ups TRUE -2 Uint16
1-16 High Speed Filter Time Const. ExpressionLimit All set-ups TRUE -2 Uint16
1-17 Voltage lter time const. ExpressionLimit All set-ups TRUE -3 Uint16
1-2* Motor Data
1-20 Motor Power [kW] ExpressionLimit All set-ups FALSE 1 Uint32
1-21 Motor Power [HP] ExpressionLimit All set-ups FALSE -2 Uint32
1-22 Motor Voltage ExpressionLimit All set-ups FALSE 0 Uint16
1-23 Motor Frequency ExpressionLimit All set-ups FALSE 0 Uint16
1-24 Motor Current ExpressionLimit All set-ups FALSE -2 Uint32
1-25 Motor Nominal Speed ExpressionLimit All set-ups FALSE 67 Uint16
1-26 Motor Cont. Rated Torque ExpressionLimit All set-ups FALSE -1 Uint32
1-28 Motor Rotation Check [0] O All set-ups FALSE - Uint8
1-29 Automatic Motor Adaptation (AMA) [0] O All set-ups FALSE - Uint8
1-3* Adv. Motor Data
1-30 Stator Resistance (Rs) ExpressionLimit All set-ups FALSE -4 Uint32
1-31 Rotor Resistance (Rr) ExpressionLimit All set-ups FALSE -4 Uint32
1-35 Main Reactance (Xh) ExpressionLimit All set-ups FALSE -4 Uint32
1-36 Iron Loss Resistance (Rfe) ExpressionLimit All set-ups FALSE -3 Uint32
1-37 d-axis Inductance (Ld) ExpressionLimit All set-ups FALSE -6 Int32
1-38 q-axis Inductance (Lq) ExpressionLimit All set-ups FALSE -6 Int32
1-39 Motor Poles ExpressionLimit All set-ups FALSE 0 Uint8
1-40 Back EMF at 1000 RPM ExpressionLimit All set-ups FALSE 0 Uint16
1-44 d-axis Inductance Sat. (LdSat) ExpressionLimit All set-ups FALSE -6 Int32
1-45 q-axis Inductance Sat. (LqSat) ExpressionLimit All set-ups FALSE -6 Int32
1-46 Position Detection Gain 120 % All set-ups TRUE 0 Uint16
1-47 Torque Calibration ExpressionLimit All set-ups TRUE - Uint8
1-48 Inductance Sat. Point ExpressionLimit All set-ups TRUE 0 Int16
1-49 q-axis Inductance Sat. Point ExpressionLimit All set-ups FALSE 0 Uint16
1-5* Load Indep. Setting
1-50 Motor Magnetisation at Zero Speed 100 % All set-ups TRUE 0 Uint16
1-51 Min Speed Normal Magnetising [RPM] ExpressionLimit All set-ups TRUE 67 Uint16
1-52 Min Speed Normal Magnetising [Hz] ExpressionLimit All set-ups TRUE -1 Uint16
1-58 Flying Start Test Pulses Current ExpressionLimit All set-ups FALSE 0 Uint16
1-59 Flying Start Test Pulses Frequency ExpressionLimit All set-ups FALSE 0 Uint16
1-6* Load Depen. Setting
1-60 Low Speed Load Compensation 100 % All set-ups TRUE 0 Int16
1-61 High Speed Load Compensation 100 % All set-ups TRUE 0 Int16
1-62 Slip Compensation 0 % All set-ups TRUE 0 Int16
1-63 Slip Compensation Time Constant ExpressionLimit All set-ups TRUE -2 Uint16
1-64 Resonance Dampening ExpressionLimit All set-ups TRUE 0 Uint16
1-65 Resonance Dampening Time Constant 5 ms All set-ups TRUE -3 Uint8
1-66 Min. Current at Low Speed ExpressionLimit All set-ups TRUE 0 Uint8
1-7* Start Adjustments
1-70 Start Mode [1] Parking All set-ups TRUE - Uint8
1-71 Start Delay 00 s All set-ups TRUE -1 Uint16
1-72 Start Function ExpressionLimit All set-ups TRUE - Uint8
1-73 Flying Start ExpressionLimit All set-ups TRUE - Uint8
1-77 Compressor Start Max Speed [RPM] ExpressionLimit All set-ups TRUE 67 Uint16
1-78 Compressor Start Max Speed [Hz] ExpressionLimit All set-ups TRUE -1 Uint16
1-79 Compressor Start Max Time to Trip 5 s All set-ups TRUE -1 Uint8
1-8* Stop Adjustments
1-80 Function at Stop [0] Coast All set-ups TRUE - Uint8
1-81 Min Speed for Function at Stop [RPM] ExpressionLimit All set-ups TRUE 67 Uint16
1-82 Min Speed for Function at Stop [Hz] ExpressionLimit All set-ups TRUE -1 Uint16
1-86 Trip Speed Low [RPM] ExpressionLimit All set-ups TRUE 67 Uint16
1-87 Trip Speed Low [Hz] ExpressionLimit All set-ups TRUE -1 Uint16
Parameter Lists Programming Guide
M0010001 Danfoss A/S © 10/2019 All rights reserved. 293
5 5