5.1.29 36-** Programmable I/O Option
Parameter
number
Parameter description Default value 4-set-up Change
during
operation
Conver-
sion index
Type
36-0* I/O Mode
36-00 Terminal X49/1 Mode [1] Voltage All set-ups TRUE - Uint8
36-01 Terminal X49/3 Mode [1] Voltage All set-ups TRUE - Uint8
36-02 Terminal X49/5 Mode [1] Voltage All set-ups TRUE - Uint8
36-03 Terminal X49/7 Mode [0] Voltage 0-10V All set-ups TRUE - Uint8
36-04 Terminal X49/9 Mode [0] Voltage 0-10V All set-ups TRUE - Uint8
36-05 Terminal X49/11 Mode [0] Voltage 0-10V All set-ups TRUE - Uint8
36-1* Analog Input X49/1
36-10 Terminal X49/1 Low Voltage 0.07 V All set-ups TRUE -2 Int16
36-11 Terminal X49/1 Low Current 4 mA All set-ups TRUE -5 Int16
36-12 Terminal X49/1 High Voltage 10 V All set-ups TRUE -2 Int16
36-13 Terminal X49/1 High Current 20 mA All set-ups TRUE -5 Int16
36-14 Term. X49/1 Low Ref./Feedb. Value 0 N/A All set-ups TRUE -3 Int32
36-15 Term. X49/1 High Ref./Feedb. Value 100 N/A All set-ups TRUE -3 Int32
36-16 Term. X49/1 Filter Time Constant 0.005 s All set-ups TRUE -3 Uint16
36-17 Term. X49/1 Live Zero [1] Enabled All set-ups TRUE - Uint8
36-2* Analog Input X49/3
36-20 Terminal X49/3 Low Voltage 0.07 V All set-ups TRUE -2 Int16
36-21 Terminal X49/3 Low Current 4 mA All set-ups TRUE -5 Int16
36-22 Terminal X49/3 High Voltage 10 V All set-ups TRUE -2 Int16
36-23 Terminal X49/3 High Current 20 mA All set-ups TRUE -5 Int16
36-24 Term. X49/3 Low Ref./Feedb. Value 0 N/A All set-ups TRUE -3 Int32
36-25 Term. X49/3 High Ref./Feedb. Value 100 N/A All set-ups TRUE -3 Int32
36-26 Term. X49/3 Filter Time Constant 0.005 s All set-ups TRUE -3 Uint16
36-27 Term. X49/3 Live Zero [1] Enabled All set-ups TRUE - Uint8
36-3* Analog Input X49/5
36-30 Terminal X49/5 Low Voltage 0.07 V All set-ups TRUE -2 Int16
36-31 Terminal X49/5 Low Current 4 mA All set-ups TRUE -5 Int16
36-32 Terminal X49/5 High Voltage 10 V All set-ups TRUE -2 Int16
36-33 Terminal X49/5 High Current 20 mA All set-ups TRUE -5 Int16
36-34 Term. X49/5 Low Ref./Feedb. Value 0 N/A All set-ups TRUE -3 Int32
36-35 Term. X49/5 High Ref./Feedb. Value 100 N/A All set-ups TRUE -3 Int32
36-36 Term. X49/5 Filter Time Constant 0.005 s All set-ups TRUE -3 Uint16
36-37 Term. X49/5 Live Zero [1] Enabled All set-ups TRUE - Uint8
36-4* Output X49/7
36-40 Terminal X49/7 Analogue Output [0] No operation All set-ups TRUE - Uint8
36-41 Terminal X49/7 Digital Output [0] No operation All set-ups TRUE - Uint8
36-42 Terminal X49/7 Min. Scale 0 % All set-ups TRUE -2 Int16
36-43 Terminal X49/7 Max. Scale 100 % All set-ups TRUE -2 Int16
36-44 Terminal X49/7 Bus Control 0 % All set-ups TRUE -2 N2
36-45 Terminal X49/7 Timeout Preset 0 % 1 set-up TRUE -2 Uint16
36-5* Output X49/9
36-50 Terminal X49/9 Analogue Output [0] No operation All set-ups TRUE - Uint8
36-51 Terminal X49/9 Digital Output [0] No operation All set-ups TRUE - Uint8
36-52 Terminal X49/9 Min. Scale 0 % All set-ups TRUE -2 Int16
36-53 Terminal X49/9 Max. Scale 100 % All set-ups TRUE -2 Int16
36-54 Terminal X49/9 Bus Control 0 % All set-ups TRUE -2 N2
36-55 Terminal X49/9 Timeout Preset 0 % 1 set-up TRUE -2 Uint16
36-6* Output X49/11
36-60 Terminal X49/11 Analogue Output [0] No operation All set-ups TRUE - Uint8
36-61 Terminal X49/11 Digital Output [0] No operation All set-ups TRUE - Uint8
36-62 Terminal X49/11 Min. Scale 0 % All set-ups TRUE -2 Int16
36-63 Terminal X49/11 Max. Scale 100 % All set-ups TRUE -2 Int16
36-64 Terminal X49/11 Bus Control 0 % All set-ups TRUE -2 N2
36-65 Terminal X49/11 Timeout Preset 0 % 1 set-up TRUE -2 Uint16
5.1.30 40-** Special Settings
Parameter
number
Parameter description Default value 4-set-up Change
during
operation
Conver-
sion index
Type
40-4* Extend. Alarm Log
40-40 Alarm Log: Ext. Reference 0 % All set-ups FALSE -1 Int16
Parameter Lists Programming Guide