5.1.9 8-** Communication and Options
Parameter
number
Parameter description Default value 4-set-up Change
during
operation
Conver-
sion index
Type
8-0* General Settings
8-01 Control Site ExpressionLimit All set-ups TRUE - Uint8
8-02 Control Source ExpressionLimit All set-ups TRUE - Uint8
8-03 Control Timeout Time ExpressionLimit 1 set-up TRUE -1 Uint32
8-04 Control Timeout Function [0] O 1 set-up TRUE - Uint8
8-05 End-of-Timeout Function [1] Resume set-up 1 set-up TRUE - Uint8
8-06 Reset Control Timeout [0] Do not reset All set-ups TRUE - Uint8
8-07 Diagnosis Trigger [0] Disable 2 set-ups TRUE - Uint8
8-08 Readout Filtering ExpressionLimit All set-ups TRUE - Uint8
8-09 Communication Charset ExpressionLimit 2 set-ups TRUE - Uint8
8-1* Control Settings
8-10 Control Prole [0] FC prole All set-ups TRUE - Uint8
8-13 Congurable Status Word STW [1] Prole Default All set-ups TRUE - Uint8
8-14 Congurable Control Word CTW [1] Prole default All set-ups TRUE - Uint8
8-3* FC Port Settings
8-30 Protocol ExpressionLimit 1 set-up TRUE - Uint8
8-31 Address ExpressionLimit 1 set-up TRUE 0 Uint8
8-32 Baud Rate ExpressionLimit 1 set-up TRUE - Uint8
8-33 Parity / Stop Bits ExpressionLimit 1 set-up TRUE - Uint8
8-34 Estimated cycle time 0 ms 2 set-ups TRUE -3 Uint32
8-35 Minimum Response Delay ExpressionLimit 1 set-up TRUE -3 Uint16
8-36 Maximum Response Delay ExpressionLimit 1 set-up TRUE -3 Uint16
8-37 Maximum Inter-Char Delay ExpressionLimit 1 set-up TRUE -5 Uint16
8-39 Protocol Firmware version 0 N/A All set-ups FALSE 0
VisStr[1
0]
8-4* FC MC protocol set
8-40 Telegram Selection [1] Standard telegram 1 2 set-ups TRUE - Uint8
8-42 PCD Write Conguration ExpressionLimit 2 set-ups TRUE - Uint16
8-43 PCD Read Conguration ExpressionLimit 2 set-ups TRUE - Uint16
8-5* Digital/Bus
8-50 Coasting Select [3] Logic OR All set-ups TRUE - Uint8
8-52 DC Brake Select ExpressionLimit All set-ups TRUE - Uint8
8-53 Start Select [3] Logic OR All set-ups TRUE - Uint8
8-54 Reversing Select ExpressionLimit All set-ups TRUE - Uint8
8-55 Set-up Select [3] Logic OR All set-ups TRUE - Uint8
8-56 Preset Reference Select [3] Logic OR All set-ups TRUE - Uint8
8-7* BACnet
8-70 BACnet Device Instance 1 N/A 1 set-up TRUE 0 Uint32
8-72 MS/TP Max Masters 127 N/A 1 set-up TRUE 0 Uint8
8-73 MS/TP Max Info Frames 1 N/A 1 set-up TRUE 0 Uint16
8-74 "I-Am" Service [0] Send at power-up 1 set-up TRUE - Uint8
8-75 Initialisation Password ExpressionLimit 1 set-up TRUE 0
VisStr[2
0]
8-8* FC Port Diagnostics
8-80 Bus Message Count 0 N/A All set-ups TRUE 0 Uint32
8-81 Bus Error Count 0 N/A All set-ups TRUE 0 Uint32
8-82 Slave Messages Rcvd 0 N/A All set-ups TRUE 0 Uint32
8-83 Slave Error Count 0 N/A All set-ups TRUE 0 Uint32
8-84 Slave Messages Sent 0 N/A All set-ups TRUE 0 Uint32
8-85 Slave Timeout Errors 0 N/A All set-ups TRUE 0 Uint32
8-89 Diagnostics Count 0 N/A 1 set-up TRUE 0 Int32
8-9* Bus Jog / Feedback
8-90 Bus Jog 1 Speed 100 RPM All set-ups TRUE 67 Uint16
8-91 Bus Jog 2 Speed 200 RPM All set-ups TRUE 67 Uint16
8-94 Bus Feedback 1 0 N/A 1 set-up TRUE 0 N2
8-95 Bus Feedback 2 0 N/A 1 set-up TRUE 0 N2
8-96 Bus Feedback 3 0 N/A 1 set-up TRUE 0 N2
Parameter Lists
VLT
®
HVAC Drive FC 102
298 Danfoss A/S © 10/2019 All rights reserved. M0010001
55

Table of Contents

Other manuals for Danfoss vlt FC 102

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss vlt FC 102 and is the answer not in the manual?

Danfoss vlt FC 102 Specifications

General IconGeneral
BrandDanfoss
Modelvlt FC 102
CategoryDC Drives
LanguageEnglish

Related product manuals