Parameter
number
Parameter description Default value 4-set-up Change
during
operation
Conver-
sion index
Type
16-71 Relay Output [bin] 0 N/A All set-ups FALSE 0 Int16
16-72 Counter A 0 N/A All set-ups TRUE 0 Int32
16-73 Counter B 0 N/A All set-ups TRUE 0 Int32
16-75 Analog In X30/11 0 N/A All set-ups FALSE -3 Int32
16-76 Analog In X30/12 0 N/A All set-ups FALSE -3 Int32
16-77 Analog Out X30/8 [mA] 0 N/A All set-ups FALSE -3 Int16
16-78 Analog Out X45/1 [mA] 0 N/A All set-ups FALSE -3 Int16
16-79 Analog Out X45/3 [mA] 0 N/A All set-ups FALSE -3 Int16
16-8* Fieldbus & FC Port
16-80 Fieldbus CTW 1 0 N/A All set-ups FALSE 0 V2
16-82 Fieldbus REF 1 0 N/A All set-ups FALSE 0 N2
16-84 Comm. Option STW 0 N/A All set-ups FALSE 0 V2
16-85 FC Port CTW 1 0 N/A All set-ups FALSE 0 V2
16-86 FC Port REF 1 0 N/A All set-ups FALSE 0 N2
16-87 Bus Readout Alarm/Warning 0 N/A All set-ups FALSE 0 Uint16
16-9* Diagnosis Readouts
16-90 Alarm Word 0 N/A All set-ups FALSE 0 Uint32
16-91 Alarm Word 2 0 N/A All set-ups FALSE 0 Uint32
16-92 Warning Word 0 N/A All set-ups FALSE 0 Uint32
16-93 Warning Word 2 0 N/A All set-ups FALSE 0 Uint32
16-94 Ext. Status Word 0 N/A All set-ups FALSE 0 Uint32
16-95 Ext. Status Word 2 0 N/A All set-ups FALSE 0 Uint32
16-96 Maintenance Word 0 N/A All set-ups FALSE 0 Uint32
16-97 Alarm Word 3 0 N/A All set-ups FALSE 0 Uint32
16-98 Warning Word 3 0 N/A All set-ups FALSE 0 Uint32
5.1.17 18-** Info & Rèadouts
Parameter
number
Parameter description Default value 4-set-up Change
during
operation
Conver-
sion index
Type
18-0* Maintenance Log
18-00 Maintenance Log: Item 0 N/A All set-ups FALSE 0 Uint8
18-01 Maintenance Log: Action 0 N/A All set-ups FALSE 0 Uint8
18-02 Maintenance Log: Time 0 s All set-ups FALSE 0 Uint32
18-03 Maintenance Log: Date and Time ExpressionLimit All set-ups FALSE 0 TimeOfDay
18-1* Fire Mode Log
18-10 FireMode Log:Event 0 N/A All set-ups FALSE 0 Uint8
18-11 Fire Mode Log: Time 0 s All set-ups FALSE 0 Uint32
18-12 Fire Mode Log: Date and Time ExpressionLimit All set-ups FALSE 0 TimeOfDay
18-3* Inputs & Outputs
18-30 Analog Input X42/1 0 N/A All set-ups FALSE -3 Int32
18-31 Analog Input X42/3 0 N/A All set-ups FALSE -3 Int32
18-32 Analog Input X42/5 0 N/A All set-ups FALSE -3 Int32
18-33 Analog Out X42/7 [V] 0 N/A All set-ups FALSE -3 Int16
18-34 Analog Out X42/9 [V] 0 N/A All set-ups FALSE -3 Int16
18-35 Analog Out X42/11 [V] 0 N/A All set-ups FALSE -3 Int16
18-36 Analog Input X48/2 [mA] 0 N/A All set-ups TRUE -3 Int32
18-37 Temp. Input X48/4 0 N/A All set-ups TRUE 0 Int16
18-38 Temp. Input X48/7 0 N/A All set-ups TRUE 0 Int16
18-39 Temp. Input X48/10 0 N/A All set-ups TRUE 0 Int16
18-4* PGIO Data Readouts
18-40 Analog Input X49/1 0 N/A All set-ups FALSE -3 Int32
18-41 Analog Input X49/3 0 N/A All set-ups FALSE -3 Int32
18-42 Analog Input X49/5 0 N/A All set-ups FALSE -3 Int32
18-43 Analog Out X49/7 0 N/A All set-ups FALSE -3 Int16
18-44 Analog Out X49/9 0 N/A All set-ups FALSE -3 Int16
18-45 Analog Out X49/11 0 N/A All set-ups FALSE -3 Int16
18-46 X49 Digital Output [bin] 0 N/A All set-ups FALSE 0 Int16
18-5* Ref. & Feedb.
18-50 Sensorless Readout [unit] 0 SensorlessUnit All set-ups FALSE -3 Int32
18-57 Air Pressure to Flow Air Flow 0 AirPresToFlowUnit All set-ups TRUE 0 Uint32
18-6* Inputs & Outputs 2
18-60 Digital Input 2 0 N/A All set-ups FALSE 0 Uint16
18-7* Rectier Status
Parameter Lists Programming Guide
M0010001 Danfoss A/S © 10/2019 All rights reserved. 305