Parameter
number
Parameter description Default value 4-set-up Change
during
operation
Conver-
sion index
Type
15-07 Reset Running Hours Counter [0] Do not reset All set-ups TRUE - Uint8
15-08 Number of Starts 0 N/A All set-ups FALSE 0 Uint32
15-1* Data Log Settings
15-10 Logging Source 0 2 set-ups TRUE - Uint16
15-11 Logging Interval ExpressionLimit 2 set-ups TRUE -3 TimD
15-12 Trigger Event [0] False 1 set-up TRUE - Uint8
15-13 Logging Mode [0] Log always 2 set-ups TRUE - Uint8
15-14 Samples Before Trigger 50 N/A 2 set-ups TRUE 0 Uint8
15-15 Info Message: "Service Log Full" [0] Disabled 1 set-up TRUE - Uint8
15-2* Historic Log
15-20 Historic Log: Event 0 N/A All set-ups FALSE 0 Uint8
15-21 Historic Log: Value 0 N/A All set-ups FALSE 0 Uint32
15-22 Historic Log: Time 0 ms All set-ups FALSE -3 Uint32
15-23 Historic log: Date and Time ExpressionLimit All set-ups FALSE 0
TimeOfDa
y
15-3* Alarm Log
15-30 Alarm Log: Error Code 0 N/A All set-ups FALSE 0 Uint16
15-31 Alarm Log: Value 0 N/A All set-ups FALSE 0 Int16
15-32 Alarm Log: Time 0 s All set-ups FALSE 0 Uint32
15-33 Alarm Log: Date and Time ExpressionLimit All set-ups FALSE 0
TimeOfDa
y
15-4* Drive Identication
15-40 FC Type 0 N/A All set-ups FALSE 0 VisStr[6]
15-41 Power Section 0 N/A All set-ups FALSE 0 VisStr[20]
15-42 Voltage 0 N/A All set-ups FALSE 0 VisStr[20]
15-43 Software Version 0 N/A All set-ups FALSE 0 VisStr[5]
15-44 Ordered Typecode String 0 N/A All set-ups FALSE 0 VisStr[40]
15-45 Actual Typecode String 0 N/A All set-ups FALSE 0 VisStr[40]
15-46 Frequency Converter Ordering No 0 N/A All set-ups FALSE 0 VisStr[8]
15-47 Power Card Ordering No 0 N/A All set-ups FALSE 0 VisStr[8]
15-48 LCP Id No 0 N/A All set-ups FALSE 0 VisStr[20]
15-49 SW ID Control Card 0 N/A All set-ups FALSE 0 VisStr[20]
15-50 SW ID Power Card 0 N/A All set-ups FALSE 0 VisStr[20]
15-51 Frequency Converter Serial Number 0 N/A All set-ups FALSE 0 VisStr[10]
15-53 Power Card Serial Number 0 N/A All set-ups FALSE 0 VisStr[19]
15-54 Cong File Name ExpressionLimit All set-ups FALSE 0 VisStr[16]
15-55 Vendor URL 0 N/A All set-ups FALSE 0 VisStr[40]
15-56 Vendor Name 0 N/A All set-ups FALSE 0 VisStr[40]
15-58 Smart Setup Filename ExpressionLimit All set-ups TRUE 0 VisStr[16]
15-59 Filename ExpressionLimit All set-ups FALSE 0 VisStr[16]
15-6* Option Ident
15-60 Option Mounted 0 N/A All set-ups FALSE 0 VisStr[30]
15-61 Option SW Version 0 N/A All set-ups FALSE 0 VisStr[20]
15-62 Option Ordering No 0 N/A All set-ups FALSE 0 VisStr[8]
15-63 Option Serial No 0 N/A All set-ups FALSE 0 VisStr[18]
15-64 Application Version 0 N/A All set-ups FALSE 0 VisStr[30]
15-70 Option in Slot A 0 N/A All set-ups FALSE 0 VisStr[30]
15-71 Slot A Option SW Version 0 N/A All set-ups FALSE 0 VisStr[20]
15-72 Option in Slot B 0 N/A All set-ups FALSE 0 VisStr[30]
15-73 Slot B Option SW Version 0 N/A All set-ups FALSE 0 VisStr[20]
15-74 Option in Slot C0/E0 0 N/A All set-ups FALSE 0 VisStr[30]
15-75 Slot C0/E0 Option SW Version 0 N/A All set-ups FALSE 0 VisStr[20]
15-76 Option in Slot C1/E1 0 N/A All set-ups FALSE 0 VisStr[30]
15-77 Slot C1/E1 Option SW Version 0 N/A All set-ups FALSE 0 VisStr[20]
15-8* Operating Data II
15-80 Fan Running Hours 0 h All set-ups TRUE 74 Uint32
15-81 Preset Fan Running Hours 0 h All set-ups TRUE 74 Uint32
15-9* Parameter Info
15-92 Dened Parameters 0 N/A All set-ups FALSE 0 Uint16
15-93 Modied Parameters 0 N/A All set-ups FALSE 0 Uint16
15-98 Drive Identication 0 N/A All set-ups FALSE 0 VisStr[40]
15-99 Parameter Metadata 0 N/A All set-ups FALSE 0 Uint16
Parameter Lists Programming Guide
M0010001 Danfoss A/S © 10/2019 All rights reserved. 303
5 5