ENTER/EXIT PROGRAMMING MODE 1D SYMBOLOGIES
192
QUICKSCAN™ 2500
Plessey Set Length 1
This feature specifies one of the bar code lengths for "Plessey Length Control" on page
191
. Length 1 is the minimum label length if in Variable Length Mode, or the first fixed
length if in Fixed Length Mode. The length includes the bar code’s check and data char-
acters.
The length can be set from 1 to 50 characters. See "
Set Length 1" on page 288 for more
detailed programming instructions.
Plessey Set Length 2
This feature specifies one of the bar code lengths for "Plessey Length Control" on page
191
. Length 2 is the maximum label length if in Variable Length Mode, or the second
fixed length if in Fixed Length Mode. The length includes the bar code’s check and data
characters.
Length can be set from 1 to 50 characters. A setting of 00 specifies to ignore this length
(only one fixed length). See "
Set Length 2" on page 289 for more detailed programming
instructions.
Select Plessey Length 1 Setting
$CPLL1
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in Appendix D, Keypad represent-
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
Length 1 = 01 (one character)
Select Plessey Length 2 Setting
$CPLL2
To configure this feature, scan the ENTER/EXIT PRO-
GRAMMING MODE bar code above, then the bar
code at left followed by the digits from the Alphanu-
meric characters in Appendix D, Keypad represent-
ing your desired character(s). End by scanning the
ENTER/EXIT bar code again.
Make a mistake? Scan the CANCEL bar code to abort
and not save the entry string. You can then start
again at the beginning.
CANCEL
Length 2 = 50 (50 characters)

Table of Contents

Other manuals for Datalogic QuickScan 2500 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic QuickScan 2500 Series and is the answer not in the manual?

Datalogic QuickScan 2500 Series Specifications

General IconGeneral
BrandDatalogic
ModelQuickScan 2500 Series
CategoryBarcode Reader
LanguageEnglish

Related product manuals