REFERENCES
280
QUICKSCAN™ 2500
SCANNING FEATURES
Scan Mode
Selects the scan operating mode for the reader. Selections are:
Trigger Single:
When the trigger is pulled, scanning is activated until one of the follow-
ing occurs:
• Stand Mode/Object Detection has elapsed
• a label has been read
• the trigger is released
This mode is associated with typical handheld reader operation: when the trigger is
pulled, scanning starts and the product scans until the trigger is released, or a label is
read, or the maximum Stand Mode/Object Detection has elapsed.
Trigger Hold Multiple:
When the trigger is pulled, scanning starts and the product
scans until the trigger is released or Stand Mode/Object Detection has elapsed. Reading
a label does not disable scanning.
Double Read Timeout prevents undesired multiple
reads of the same label while in this mode.
Trigger Pulse Multiple:
When the trigger is pulled, continuous scanning is activated
until Stand Mode/Object Detection has elapsed or the trigger has been released and
pulled again.
Double Read Timeout prevents undesired multiple reads of the same label
while in this mode.
Flashing:
The reader flashes
1
on and off regardless of the trigger status. Flash rate is
controlled by
Flash On Time and Flash Off Time. When Flash is ON the reader reads con-
tinuously. When Flash is OFF scanning is deactivated.
Always On:
No trigger pull is required to read a bar code. Scanning is continually on.
Double Read Timeout prevents undesired multiple reads of the same label while in this
mode.
Stand Mode/Object Detection:
No trigger pull is required to read a bar code. Scanning
turns on automatically when an item is placed in reader's field of view. While in a stand
watch state, the reader illumination LED goes from dim to maximum bright.
Trigger Object Sense:
The reader detects changes within its field-of-view and auto-
matically turns on the illuminator. Decoding is not automatic. To decode it is necessary
to pull the trigger.
Scanning Active Time
This setting specifies the amount of time that the reader stays in scan ON state once the
state is entered. The range for this setting is from 1 to 255 seconds in 1-second incre-
ments.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three digits. For example: 0 = 000, 5 =
005, 20 = 020, etc.
1. Controlled by Flash On Time.