ENTER/EXIT PROGRAMMING MODE 1D SYMBOLOGIES
194
QUICKSCAN™ 2500
BC412 Length Control
This feature specifies either variable length decoding or fixed length decoding for the
BC412 symbology.
Variable Length: For variable-length decoding, a minimum length may be set.
Fixed Length: For fixed-length decoding, two different lengths may be set.
$CBCLC00
BC412 Length Control = Variable Length
BC412 Length Control = Fixed Length
$CBCLC01