EasyManuals Logo
Home>Dell>Server>PowerEdge FX2

Dell PowerEdge FX2 User Manual

Dell PowerEdge FX2
154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #126 background imageLoading...
Page #126 background image
NOTE: The IP address set on the IOM from CMC is not saved to the permanent startup configuration of the switch.
To permanently save the IP address configuration, you must run the connect switch command, or racadm
connect switch RACADM command, or use a direct interface to the IOM GUI to save this address to the startup
configuration file.
NOTE: The length of the SNMP community string can be in the ASCII value range of 33–125 characters.
3. Click Apply.
The network settings are configured for the IOM.
NOTE: If allowed, you can reset the VLANs, network properties, and IO ports to its default configuration values.
Configuring network settings for IOM using RACADM
To configure the network settings for an IOM by using RACADM, set the date and time. See the deploy command section in the Dell
Chassis Management Controller for PowerEdge FX2/FX2s RACADM Command Line Reference Guide
.
You can set the user name, password, and SNMP string for the IOM using the RACADM deploy command:
racadm deploy -m switch -u <username> -p <password>
racadm deploy -m switch -u -p <password> -v SNMPv2 <snmpCommunityString> ro
racadm deploy -a [server|switch] -u <username> -p <password>
Viewing I/O module uplink and downlink status using web interface
NOTE: This feature is available only in PowerEdge FX2/FX2s.
You can view the uplink and downlink status information for Dell PowerEdge M I/O Aggregator using the CMC Web interface. To do
this:
1. Go to Chassis OverviewI/O Module Overview.
All the IOMs (1–2) appear in the expanded list.
2. Click the IOM (slot) you want to view.
The I/O Module Status page specific to the IOM slot is displayed. The I/O Module Uplink Status and I/O Module Downlink
Status tables are displayed. These tables display information about the downlink ports (1-8) and uplink ports (9-12). For more
information, see the CMC for Dell PowerEdge FX2/FX2s Online Help.
Viewing I/O module FCoE session information using web interface
You can view the FCoE session information for Dell PowerEdge M I/O Aggregator using the CMC web interface. To do this:
1. Go to Chassis OverviewI/O Module Overview.
All the IOMs (2) appear in the expanded list.
2. Click the IOM (slot) you want to view. Click PropertiesFCoE.
The FCoE I/O Module page specific to the IOM slot is displayed.
3. In the Select Port drop-down, select the required port number for the selected IOM and click Show Sessions. The selected
option retrieves the FCoE session information for the switch, and present it to the user as a table.
The FCoE Session Information section displays the FCoE session information for the switch.
NOTE: The I/O Aggregator also displays the active FCoE sessions when the switch is using the protocol.
Resetting IOM to factory default settings
You can reset IOM to the factory default settings using the Deploy I/O Modules page.
126

Table of Contents

Other manuals for Dell PowerEdge FX2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge FX2 and is the answer not in the manual?

Dell PowerEdge FX2 Specifications

General IconGeneral
Product colorBlack, Silver
Rack capacity2U
LED indicatorsYes
Number of fans8 fan(s)
Heat dissipation475 BTU/h
Dell E-Value CodePEFX2Chassis
Input current25 A
AC input voltage100 - 240 V
Power requirements1600W
Operating altitude0 - 3048 m
Storage temperature (T-T)-40 - 65 °C
Operating temperature (T-T)10 - 35 °C
Storage relative humidity (H-H)5 - 95 %
Operating relative humidity (H-H)10 - 80 %
Weight and Dimensions IconWeight and Dimensions
Depth851.6 mm
Width433.5 mm
Height86.8 mm

Related product manuals