19
Frequently asked questions
This section lists the frequently asked questions about the following:
RACADM
Managing and Recovering a Remote System
Active Directory
IOM
RACADM
After performing a CMC reset (using the RACADM racreset subcommand), when a command is entered, the following
message is displayed:
racadm <subcommand> Transport: ERROR: (RC=-1)
What does this message mean?
Another command must be issued only after CMC completes the reset.
Using the RACADM subcommands sometimes displays one or more of the following errors:
Local error messages — Problems such as syntax, typographical errors, and incorrect names. For example, ERROR:
<message>
Use the RACADM help subcommand to display correct syntax and usage information. For example, if you have an error in clearing
a chassis log, run the following sub-command.
racadm chassislog help clear
CMC–related error messages — Problems where the CMC is unable to perform an action. The following error message is displayed
racadm command failed.
To view information about a chassis, type the following command.
racadm gettracelog
While using firmware RACADM, the prompt changes to a ">" and the "$" prompt is not displayed again.
If a non-matched double quotation mark (") or a non-matched single quotation (’) is used in the command, the CLI changes to the
">" prompt and queues all commands.
To return to the $ prompt, type <Ctrl>–d.
An error message Not Found is displayed while using the $ logout and $ quit commands.
Managing and recovering a remote system
When accessing the CMC Web interface, a security warning stating that the host name of the SSL certificate does not match
the host name of CMC is displayed.
CMC includes a default CMC server certificate to ensure network security for the web interface and remote RACADM features.
When this certificate is used, the web browser displays a security warning because the default certificate is issued to CMC default
certificate which does not match the host name of CMC (for example, the IP address).
To address this security concern, upload a CMC server certificate issued to the IP address of CMC. When generating the certificate
signing request (CSR) to be used for issuing the certificate, ensure that the common name (CN) of the CSR matches the IP
address of CMC (for example, 192.168.0.120) or the registered DNS CMC name.
152

Table of Contents

Other manuals for Dell PowerEdge FX2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge FX2 and is the answer not in the manual?

Dell PowerEdge FX2 Specifications

General IconGeneral
Product colorBlack, Silver
Rack capacity2U
LED indicatorsYes
Number of fans8 fan(s)
Heat dissipation475 BTU/h
Dell E-Value CodePEFX2Chassis
Input current25 A
AC input voltage100 - 240 V
Power requirements1600W
Operating altitude0 - 3048 m
Storage temperature (T-T)-40 - 65 °C
Operating temperature (T-T)10 - 35 °C
Storage relative humidity (H-H)5 - 95 %
Operating relative humidity (H-H)10 - 80 %
Weight and Dimensions IconWeight and Dimensions
Depth851.6 mm
Width433.5 mm
Height86.8 mm