Page #141 background imageLoading...
Page #141 background image
to the compute sleds in the lower bay earlier, are mapped to corresponding compute sleds in the upper bay. Following are some
examples for PCIe reassignment:
PCIe reassignment in full-width (FW) FC830:
PCIe slots mapped to FW sled-3 (PCIe slots 1 through 4) are reassigned to sled–1. Sled-1 now maps to PCIe slots 1 though 8.
PCIe reassignment in half-width (HW) FC630:
PCIe slots mapped to HW sled-3 (PCIe slots 5 and 6) are reassigned to sled-1. Sled-1 now maps to PCIe slots 5 through 8.
PCIe slots mapped to HW sled-4 (PCIe slots 1 and 2) are reassigned to sled-2. Sled-2 now maps to PCIe slots 1 through 4.
PCIe reassignment in quarter-width (QW) FC430:
PCIe slot mapped to QW sled-3a (PCIe slot 6) is reassigned to sled-1a. Sled-1a now maps to PCIe slots 6 and 8.
PCIe slot mapped to QW sled-3b (PCIe slot 5) is reassigned to sled-1b. Sled-1b now maps to PCIe slots 5 and 7.
PCIe slot mapped to QW sled-3c (PCIe slot 2) is reassigned to sled-1c. Sled-1c now maps to PCIe slots 2 and 4.
PCIe slot mapped to QW sled-3d (PCIe slot 1) is reassigned to sled-1d. Sled-1d now maps to PCIe slots 1 and 3.
For more information, see the Dell PowerEdge FX2 and FX2s Enclosure Owner's Manual.
Enabling or disabling the PCIe reassignments using CMC web interface
1. In the left pane, click PCIe Overview.
The PCIe Status page is displayed.
2. Click Setup.
The Mapping: PCIe Slot Reassignment page is displayed.
3. Select or clear the Enable PCIe Slot Reassignment check box and click Apply.
Enabling or disabling PCIe reassignments using RACADM
The input values for enabling or disabling the PCIe reassignment to a slot are:
1 — Enable
0 — Disable
To enable a PCIe reassignment, run the following command:
racadm config –g cfgPCIe –o cfgPCIeReassignmentEnable 1
To disable a PCIe reassignment, run the following command:
racadm config –g cfgPCIe –o cfgPCIeReassignmentEnable 0
For more information, see the Dell Chassis Management Controller for PowerEdge FX2/FX2s RACADM Command Line Reference
Guide available at dell.com/support/Manuals.
141

Table of Contents

Other manuals for Dell PowerEdge FX2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge FX2 and is the answer not in the manual?

Dell PowerEdge FX2 Specifications

General IconGeneral
Product colorBlack, Silver
Rack capacity2U
LED indicatorsYes
Number of fans8 fan(s)
Heat dissipation475 BTU/h
Dell E-Value CodePEFX2Chassis
Input current25 A
AC input voltage100 - 240 V
Power requirements1600W
Operating altitude0 - 3048 m
Storage temperature (T-T)-40 - 65 °C
Operating temperature (T-T)10 - 35 °C
Storage relative humidity (H-H)5 - 95 %
Operating relative humidity (H-H)10 - 80 %
Weight and Dimensions IconWeight and Dimensions
Depth851.6 mm
Width433.5 mm
Height86.8 mm