EasyManuals Logo

Dell PowerEdge FX2 User Manual

Dell PowerEdge FX2
154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #98 background imageLoading...
Page #98 background image
Privilege Description
NOTE: CMC users with the Chassis Configuration Administrator privilege
can configure power settings. However, the Chassis Control Administrator
privilege is required to perform chassis power operations, including power
on, power off, and power cycle.
User Configuration Administrator User can:
Add a new user.
Change the password of a user.
Change the privileges of a user.
Enable or disable the login privilege of a user but retain the name and other
privileges of the user in the database.
Clear Logs Administrator User can clear the hardware log and CMC log.
Chassis Control Administrator (Power
Commands)
CMC users with the Chassis Power Administrator privilege can perform all power-
related operations. They can control chassis power operations, including power on,
power off, and power cycle.
NOTE: To configure power settings, the Chassis Configuration
Administrator privilege is needed.
Server Administrator This is a blanket privilege, granting a CMC user all rights to perform any operation on
any servers present in the chassis.
When a user with Server Administrator privilege issues an action to be performed
on a server, the CMC firmware sends the command to the targeted server without
checking the privileges of a user on the server. In other words, the Server
Administrator privilege overrides any lack of administrator privileges on the server.
Without the Server Administrator privilege, a user created on the chassis can only
execute a command on a server when all of the following conditions are true:
The same user name exists on the server.
The same user name must have the same password on the server.
The user must have the privilege to execute the command.
When a CMC user who does not have Server Administrator privilege issues an
action to be performed on a server, CMC sends a command to the targeted server
with the user’s login name and password. If the user does not exist on the server, or
if the password does not match, the user is denied the ability to perform the action.
If the user exists on the target server and the password matches, the server
responds with the privileges of which the user was granted on the server. Based on
the privileges responding from the server, CMC firmware decides if the user has the
right to perform the action.
Listed below are the privileges and the actions on the server to which the Server
Administrator is entitled. These rights are applied only when the chassis user does
not have the Server Administrative privilege on the chassis.
Server Configuration Administrator:
Set IP address
Set gateway
Set subnet mask
Set first boot device
Configure Users:
Set iDRAC root password
iDRAC reset
Server Control Administrator:
98

Table of Contents

Other manuals for Dell PowerEdge FX2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge FX2 and is the answer not in the manual?

Dell PowerEdge FX2 Specifications

General IconGeneral
Product colorBlack, Silver
Rack capacity2U
LED indicatorsYes
Number of fans8 fan(s)
Heat dissipation475 BTU/h
Dell E-Value CodePEFX2Chassis
Input current25 A
AC input voltage100 - 240 V
Power requirements1600W
Operating altitude0 - 3048 m
Storage temperature (T-T)-40 - 65 °C
Operating temperature (T-T)10 - 35 °C
Storage relative humidity (H-H)5 - 95 %
Operating relative humidity (H-H)10 - 80 %
Weight and Dimensions IconWeight and Dimensions
Depth851.6 mm
Width433.5 mm
Height86.8 mm