EasyManuals Logo
Home>Delta>Controller>DVP-SS2

Delta DVP-SS2 User Manual

Delta DVP-SS2
1006 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #555 background imageLoading...
Page #555 background image
DVP-ES2/EX2/EC5/SS2/SA2/SX2/SE&TP Operation Manual - Programming
3-434
API
Mnemonic Operands Function
Controllers
ES2/EX2/
EC5
SS2
SA2
SE
SX2
173 D
SUBR P
Floating point
subtraction
Type
OP
Bit Devices Word devices Program Steps
X Y M S K H KnX
KnY
KnM
KnS
T C D E F
DSUBR: 13 steps
S
1
*
S
2
*
D
*
PULSE
16-bit
32-bit
ES2/EX2/
EC5
SS2
SA2
SE
SX2
ES2/EX2/
EC5
SS2
SA2
SE
SX2
ES2/EX2/
EC5
SS2
SA2
SE
SX2
Operands:
S
1
: Floating point minuend S
2
: Floating point subtrahend D: Remainder
Explanations:
1. SUBR instruction subtracts S
1
with S
2
and stores the operation result in D.
2. In SUBR instruction, floating point values can be directly entered into S
1
and S
2..
3. In DSUBR instruction, floating point values (e.g. F1.2) can be either entered directly into S
1
and S
2
or stored in data registers for operation.
4. When S
1
and S
2
is specified as data registers, the function of DSUBR instruction is the same
as API 121 ESUB instruction.
5. S
1
and S
2
can designate the same register. In this case, if the instruction is specified as
“continuous execution instruction” (generally DSUBRP instruction) and the drive contact is ON,
the register will be subtracted once in every scan.
6. Flags: M1020 (Zero flag), M1021 (Borrow flag) and M1022 (Carry flag)
If absolute value of the result exceeds max floating point value, carry flag M1022 = ON.
If absolute value of the result is less than min. floating point value, borrow flag M1021 = ON.
If the conversion result is 0, zero flag M1020 = ON
Program example 1:
When X0 = ON, subtract floating point number F1.200E+0 (Input F1.2, and scientific notation
F1.200E+0 will be displayed on ladder diagram. Users can set monitoring data format as float on
the function View) with F2.200E+0 and store the obtained result F-1.000E+0 in register D10 and
D11.
X0
DSUBR F1.200E+0
D10
F2.200E+0
Program example 2:
When X0 = ON, subtract the floating point value (D1, D0) with (D3, D2) and store the result in (D11,
D10).
X0
DSUBR
D0
D2
D10

Table of Contents

Other manuals for Delta DVP-SS2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta DVP-SS2 and is the answer not in the manual?

Delta DVP-SS2 Specifications

General IconGeneral
BrandDelta
ModelDVP-SS2
CategoryController
LanguageEnglish

Related product manuals