OPERATION
3-22 EPT031055 Issue 2 September 2017
Production Line Setup
Home > Settings > Production Line Setup
Set:
•Printer Orientation
Rotates the print head and/or product to set the correct orientation.
One may mirror the print.
Set the vector sorting direction in such a way that marking is
processed in the opposite direction to the direction in which the
product is moving. If “none” is selected, the vectors will be processed
in the normal marking order of the objects.
•Print Field
Sets the usable dimension and scanner dimension of the print field:
Width, height and centre point.
Set restriction for the print field.
Trigger a test print to measure the field to setup the field size.
•Optics
Select the correction matrix for the used scanner and lens
configuration and make a test print of it.
Select the tube distortion axis to mark round objects.
•Line Movement
Product Line Movement: Static or mark on the fly.
Encoder Setup: Source, scale delay and field usage PN
Transformation.
Product Distance: Maximum distance and print start ignore distance
see “Product Distance and Print Start - Ignore Distance” on page 2-64.
Print Trigger
•Product Detect
Continuous Printing: Trigegr a print by given time interval.
Debounce Settings: Set the ramp times.
•Shift Register
Enable the shift register between trigger signal and print on the
product and set the depth.

Table of Contents

Other manuals for Domino F Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Domino F Series and is the answer not in the manual?

Domino F Series Specifications

General IconGeneral
BrandDomino
ModelF Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals