INSTALLATION INSTRUCTIONS
EPT031055 Issue 2 September 2017 2-51
SHUTTER TIMING
1
1
2
2
3
3
4
4
D D
C C
B B
A A
Date Name Date Name
Ind. Chan.No. Changing Processed Reviewed
Title:
Project:
No.: 190028
Laser / shutter timing
Fibre laser
Fiber_shutter_timing_customer-1_11-190028c.SchDoc
Date
Date see box
File:
Version: See box Page of Size: A411
D-22547 Hamburg
Germany
Sator Laser GmbH
Fangdieckstraße 75a
© Sator Laser GmbH
Domino Group
omino Laser GmbH
angdieckstraße 75a
-22547 Hamburg
Germany
© Domino Laser GmbH
Timing a00 28.11.13 HK
ow 190024 a01: With number and new location 11.12.13 HK
ow 190028 a01: Version with and without shutter 27.02.14 HK
b10: Deleted print timing activities. Deleted Safety to BCP7 and Laser PSU on lines.
Dividing shutter diagram with / without lock version. Document now for all lasers.
18.08.14 HK
c11: TÜV version with shutter an safety output test cycles time delay 10.11.14 HK
\\emea\group\Sator\Projects\Fibre_Laser\Shutter_Safety_Concept\Docu_Collection\DXP
X69 Guard door
X69:7 Start
Laser PSU on
BCP7 RDY
100ms min
200ms
5s
open
Version laser without shutter
100ms min
200ms
5s
100ms min
2.5s
5.4s
40ms
40ms
150ms
Normal workingInitial start sequence
Version laser with shutter (standard mode)
100ms min
5.4s
40ms
40ms
150ms
Normal working / closing door firstInitial start sequence
180ms
Version laser with shutter and door lock (static mode; open by start input)
50ms min *
* Unlocking time dependig on the locking device
100ms min
5.4s
40ms
40ms
150ms
Normal working / Start command firstInitial start sequence
180ms
Version laser with shutter and door lock (static mode, open by door closing)
50ms min *
* Unlocking time dependig on the locking device
closed
X69 Guard door
X69:7 Start
BCP7 RDY
open
closed
X69 Guard door
X69:7 Start
BCP7 RDY
open
closed
X69 Guard door
X69:7 Start
BCP7 RDY
open
closed
Door lock
Door lock
2.5s
2.5s
Shutter (open)
Shutter (open)
Shutter (open)