MAINTENANCE AND FAULT FINDING
5-30 EPT031055 Issue 2 September 2017
FUME EXTRACTION SYSTEM
WARNINGS: (1) Only use genuine Domino replacement parts.
Any other parts may not meet the design or
working requirements and put personnel at risk.
(2) Use the filter change kits provided with each
filter.
(3) Dispose of used filters in the plastic bag
provided in the filter change kit according to
local regulations.
General Notes
These notes are particular to the FE scheduled maintenance.
• Alarms (audible and visual): refer to the Fault Finding and Repair
section
• Instruction sheets are provided with each repair kit and not in this
manual
• The main filter is heavy, therefore care must be taken when removing
• Always check the following for debris build-up when changing a filter:
(a) Extraction nozzle
(b) Flexible hose
(c) Air inlet
Recommended Routine Maintenance
Primary maintenance is filter replacement. The fume extractor control
system will indicate when this is necessary. Experience of local conditions
may be used to formulate a periodic replacement schedule.
Daily
Visually check that fumes are being drawn into the extractor.
Weekly
Check the LCD status bars on the control panel.
Annual
Consult Domino for advice.