HEALTH & SAFETY
1-8 EPT031055 Issue 2 September 2017
Values for the fibre laser (calculated with 100mm lens and M
2
=1.6):
WARNING: Laser radiation emitted by fibre lasers can cause
irreversible damage to the retina of the eye. This
my lead to instant blindness.
Protective Safety Goggles
Domino recommends the following safety goggles:
• Protection against laser radiation: between 1040nm and1200nm.
•Energy: 2mJ
• Pulse length: 1-500ns, repetition rate: 1-1000kHz
• Beam diameter: 10-15mm
• Scale number LB8 according to DIN EN207:2009.
Domino order number L015342.
Aiming Beam / Pilot Laser
The system contains an aiming beam with a wavelength of 630nm to
670nm.
This laser is a class 3R laser with an output power of up to 5 mW.
Class 4 The accessible laser radiation may be visible or invisible. Direct
and diffuse radiation is extremely harmful to eyes and skin and
can pose a fire risk if projected onto combustible materials.
The F-Series laser marking systems, taken by themselves, are
Class 4 and must not be used until suitable, interlocked
guarding is fitted to achieve a Class 1 laser installation that
physically prevents access to the laser radiation or automatically
disables the laser when access is required to the marking area
(for cleaning or maintenance, etc.).
Power
Maximum
Average
Power Density
Energy Density
Beam Outlet 70W
2.8 W/mm
2
0.112 mJ/mm
2
Focus 70W
2415000 W/mm
2
9643 mJ/mm
2