INSTALLATION INSTRUCTIONS
2-34 EPT031055 Issue 2 September 2017
The second Ethernet interface is used for a remote panel pre-
configured to the IP address 192.168.57.2 / subnet mask
255.255.255.0.
A Laser Start Input can be connected for laser start by means of a
mechanical switch against floating GND (between pin 7 and pin 2).
Connector Type: IEC 60130-9 Type 7 way female
Mating Cable Connector (IP67 Types):
• Lumberg: 033207
Pin description
• Pin 1 +24VF - 24V floating
This pin can be used to drive a remote panel with 24V at 1.5A
• Pin 2 GNDF - Floating Ground
• Pin 3 TX+ - Transmit +
• Pin 4 TX- - Transmit –
• Pin 5 RX+ - Receive +
• Pin 6 RX- - Receive -
• Pin 7 LSTART_INP - static Laser Start Input
By applying voltage to this input the laser may be started;
including enabling of the printer.
Input level 10-30V; input impedance: 2 kOhm, referenced to Pin
2 GNDF Floating Ground. The voltage available at pin 1 may be
used.
Note: Note: This input internally works in parallel to the other (X4 and
X29) Laser Start Inputs. Thus, applying of constant voltage at
this pin will suppress edges coming from the other Laser Start
Inputs.
If in a multiple head system the install option “Laser On level sensitive” is
activated, this input can only be used for the first controller next to the
machine (“primary”) as Laser Start Input. Applying of constant voltage at
this pin of a “secondary” controller of a multiple head system would disturb
the internal communication between the controllers and would lead to
malfunction.
WARNING: Attention: this connector does not offer a “laser
switch off” input.