T3-B T6-B Manipulator 12. Standard I/O Connector
110 T-B series Rev.1
12. Standard I/O Connector
CAUTION
Be careful not to exceed rated current range or rated current which are defined
in manual.
If exceeding rated current, the Manipulator may now operate at worst.
Standard I/O Connector is a connector mounted on back side of the Manipulator for
connecting your input/output equipment to the system.
Connector name
Pins
Bit number
I/O (Input) Connector
18
0-17
I/O (Output) Connector
12
0-11
For cable wiring, refer to “3.7.2 Noise Countermeasures” in order to prevent noise.
Remote function is initially assigned to both input and output from 0 to 8. For further details,
refer to “14. I/O Remote Settings”.
Also, for details of hand I/O, refer to “13.Hand I/O Connector”.
12.1 Input Circuit
Input Voltage Range : +12 to 24 V ±10%
ON Voltage : +10.8 V (min.)
OFF Voltage : +5 V (max.)
Input Current : 10 mA (TYP) at +24 V input
Two types of wiring are available for use with the two-way photo coupler in the input circuit.

Table of Contents

Other manuals for Epson T-B Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epson T-B Series and is the answer not in the manual?

Epson T-B Series Specifications

General IconGeneral
BrandEpson
ModelT-B Series
CategoryRobotics
LanguageEnglish

Related product manuals