EasyManuals Logo
Home>Epson>Robotics>T3 Series

Epson T3 Series User Manual

Epson T3 Series
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #91 background imageLoading...
Page #91 background image
2. Installation
Safety and Installation (T, VT / EPSON RC+ 7.0) Rev.15 73
2.7.2 Power ON Procedure
(1) Check the EMERGENCY connector connection.
(2) Connect the TP bypass plug to the TP port.
(3) Connect the power cable to the Manipulator
(4) Connect the power cable to the power supply socket.
(5) The PROGRAM LED blinks approximately 30 seconds after Controller starts
up normally.
If the ERROR LED is turned ON or blinking, check connection in step (1) to
(4) and turn ON the power again.
If the ERROR LED is still ON or blinking, contact the supplier in your region.
T series Manipulator
LED
(Illustration: T3-401S)
VT series Manipulator
LED
LED
Standard model, Cleanroom model
Protection model

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epson T3 Series and is the answer not in the manual?

Epson T3 Series Specifications

General IconGeneral
BrandEpson
ModelT3 Series
CategoryRobotics
LanguageEnglish

Related product manuals