4-4
4.3 LED Status
LED status symbols:
ß
Ö
OFF ;
Þ
Ö
Blinking ;
Ý
Ö
ON
Unit
No.
Board LED No. Display
Normal
status
Remarks Location of LEDs
SPU Board
(03P9230)
CR4 (YLW)
Þ
Blinks every second.
RP Board
(03P9259)
CR2 (YLW)
CPU CLK
Þ
Blinks every second.
CR1 (RED)
HDG alarm
ß
received for more
than 10 sec.
CR2 (RED)
BRG alarm
ß
received for more
than 10 sec.
CR3 (RED)
Video
alarm
ß
received for more
than 60 sec.
CR7 (RED)
TRG alarm
ß
received for more
than 10 sec.
CR8 (YLW)
TRIG freg.
Ý
or
ß
CR9 (YLW)
TRIG
Freq.
ß
CR10 (RED)
Gyro alarm
ß
received for more
than 10 sec.
CR11 (RED)
Log alarm
ß
received for more
than 60 sec.
CR4 (YLW)
CPU
Þ
Blinks every 2 sec.
CR5 (YLW)
DSP
Þ
Blinks every seconds.
ARP Board
(18P9004)
CR12 (YLW)
QV
Þ
Looks like on.
ARP Board
(18P9007)
CR1 (YLW)
CPU
Monitor
Þ
Blinks every seconds.
CR2 (RED)
Over-/Low-
volt.
ß
Lights when ship’s
mains exceeds the
rating.
DC Power
Board
(03P9223)
CR4 (RED)
Over-cur.
ß
Lights if over-current
is detected.
CR2 (RED)
Over-volt.
ß
Display
Unit
AC Power
Board
(03P9228)
CR4 (RED)
Over-cur.
ß
Lights when ship’s
mains exceeds the
rating.
Lights if over-current
is detected.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Furuno FR-1505 MARK-3 Series and is the answer not in the manual?

Furuno FR-1505 MARK-3 Series Specifications

General IconGeneral
BrandFuruno
ModelFR-1505 MARK-3 Series
CategoryMarine Radar
LanguageEnglish

Related product manuals