4-11
4.7 How to Store Default Setting
Proceed the following steps to store default setting or change to factory setting.
1. While pressing and holding down the GAIN (HL-OFF) control, press [MENU] key five times,
and the following factory menu will appear.
2. Press [ENTER] three times.
3. Turn off the system and turn on again.
The factory menu
1) Language (Japanese/English)
2) Type (R/IMO; R: Regular; IMO; ships over 300 grt)
3) Maximum range (48 nm: 1505MK3; 72 nm: 1510MK3; 96 nm: 1525MK3)
4) Default
5) ARP-17 PRESET DATA
(appears when the ARP-17 is fitted. Do not change the data in the field.)
FR1710-SME-47