– 42 –
Daughter Relay Module (DRM)
To remove the DRM on PSH925:
1. Remove the rear cover. (See
Rear Cover.)
2. Disconnect the wire harness and mark and
disconnect wires that connect the DRM to the
range.
3. Compress the tab on each of the 4 compression
pins that attach the DRM to the range.
To remove the RPSM AUX Board on PS978:
1. Remove the rear cover. (See Rear Cover.)
2. Disconnect the wire harnesses and mark and
disconnect wires that connect the RPSM AUX
Board to the range.
3. Remove the 4 Phillips-head screws that attach
the RPSM AUX Board to the RPSM AUX Board
frame.
(Continued next page)