Troubleshooting 161
Adapter/NVRAM ID Mismatch
Description: EISA NVRAM has an ID for a different controller from the one
physically present in the slot.
Action: Run the server setup utility.
Array Accelerator Battery Pack X not Fully Charged
Description: Battery is not fully charged.
Action: If 75% of the batteries present are fully charged, the array accelerator is
fully operational. If more than 75% of the batteries are not fully charged, allow
36 hours to recharge them.
Array Accelerator Battery Pack X Below Reference Voltage (Recharging)
Description: Battery pack on the array accelerator is below the required voltage
levels.
Action: Replace the array accelerator board if the batteries do not recharge
within 36 powered-on hours.
Board in Use by Expand Operation
Description: Array accelerator memory is in use by an expand operation.
Action: Operate the system without the array accelerator board until the expand
operation completes.
Board not Attached
Description: An array controller is configured for use with array accelerator
board, but one is not connected.
Action: Connect array accelerator board to array controller.