218 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide
A CPU Power Module (System Board, Socket X)...
...A CPU Power Module (Slot X, Socket Y) Failed
Event Type: Power module failure
Action: Replace the power module. In the case of an embedded power module,
replace the system board.
ASR Lockup Detected: Cause
Event Type: System lockup
Action: Examine the IML ("Integrated Management Log" on page 80
) to
determine the cause of the lockup, and then refer to the HP ROM-Based Setup
Utility User Guide, on the server Documentation CD or at the SmartStart website
(http://h18013.www1.hp.com/products/servers/management/smartstart), for more
information.
Automatic Operating System Shutdown Initiated Due to Fan Failure
Event Type: Fan failure
Action: Replace the fan.
Automatic Operating System Shutdown Initiated Due to Overheat Condition...
...Fatal Exception (Number X, Cause)
Event Type: Overheating condition
Action: Check fans. Also, be sure the server is properly ventilated and the room
temperature is set within the required range.
Blue Screen Trap: Cause [NT]...
...Kernel Panic: Cause [UNIX]
Abnormal Program Termination: Cause [NetWare]