204 HP ProLiant DL360 Generation 4 Server Reference and Troubleshooting Guide
209-Online Spare Memory Configuration - No Valid Banks for Online
Spare
Audible Beeps: 1 long, 1 short
Possible Cause: Two valid banks are not available to support an online spare
memory configuration.
Action: Install or reinstall DIMMs to support online spare configuration.
209-Online Spare Memory Configuration - Spare Bank is Invalid
Audible Beeps: 1 long, 1 short
Possible Cause: Installed DIMMs for online spare bank are of a size smaller than
another bank.
Action: Install or reinstall DIMMs to support online spare configuration.
212-Processor Failed, Processor X
Audible Beeps: 1 short
Possible Cause: Processor in slot X failed.
Action: Run Insight Diagnostics ("HP Insight Diagnostics" on page 80) and
replace failed components as indicated.
214-Processor PPM Failed, Module X
Audible Beeps: None
Possible Cause: Indicated PPM failed.
Action: Run Insight Diagnostics ("HP Insight Diagnostics" on page 80
) and
replace failed components as indicated.