Troubleshooting 189
Critical Error Occurred Prior to this Power-Up
Audible Beeps: None
Possible Cause: A catastrophic system error, which caused the server to crash,
has been logged.
Action: Run Insight Diagnostics ("HP Insight Diagnostics" on page 80
) and
replace failed components as indicated.
Fan Solution Not Fully Redundant
Audible Beeps:
Possible Cause: The minimum number of required fans are installed, but some
redundant fans are missing or failed.
Action: Install fans or replace failed fans to complete redundancy.
Fan Solution Not Sufficient
Audible Beeps:
Possible Cause: The minimum number of required fans are missing or failed.
Action: Install fans or replace any failed fans.
Fatal DMA Error
Audible Beeps: None
Possible Cause: The DMA controller has experienced a critical error that has
caused an NMI.
Action: Run Insight Diagnostics and replace failed components as indicated.