87
Chapter 4: Configuring the Emulation Probe/Module
Testing the Emulation Probe/Module and the Target System
Testing the Emulation Probe/Module and the
Target System
After you have connected and configured the emulation probe/module,
you should perform some simple tests to verify that everything is
working.
See Also See “Solving Emulation Probe Problems” on page 135 or “Solving
Emulation Module Problems” on page 143 for information on testing
the emulation probe/module hardware.
To test memory accesses
1 Start the Emulation Control Interface and configure the
emulation probe/module, if necessary.
2 Open the Memory window.
3 Write individual locations or fill blocks of memory with patterns
of your choosing.
The access size is the size of memory access that will be used to write
or read the memory values.
4 Use the Memory I/O window to stimulate I/O locations by reading
and writing individual memory locations.
To test by running a program
To more fully test your target, you can load simple programs and
execute them.
1 Compile or assemble a small program and store it in a Motorola S-
Record or Intel Hex file.