Page #95 background imageLoading...
Page #95 background image
93
Chapter 5: Using Debuggers
Setting Up Debugger Software
To change the port number of an emulation
probe/module
Some debuggers do not provide a way to specify an emulation probe/
module port number. In this case:
The debugger will always connect to port 6470 (the default port number of
an emulation probe, or the port number of the emulation module in slot 1
of an HP 16600A/16700A-series logic analysis system).
If the port number of the emulation probe/module is not 6470, you must
change it.
To change the port number of an emulation probe, see “To configure
LAN parameters using the built-in terminal interface” on page 23.
To change the port number of an emulation module, see “To change the
port number of an emulation module” on page 60.
To view logic analysis system windows next to
the debugger
1 Make sure the computer running the debugger is also running
X Windows server software and has telnet software.
2 Give the logic analysis system permission to display on the
X Windows server.
3 Connect to the logic analysis system, log in, and start a session,
displaying on the X Windows server.