Parameter Condition Requirement
Non-operating ambient
temperature
-40°C to +70°C (-40°F to +158°F)
Storage temperature
(during transportation
and storage with
packages)
-40°C to +70°C (-40°F to +158°F)
Humidity Operating humidity
10% RH
a
to 90% RH
Non-operating ambient
humidity
5% RH to 95% RH
Maximum humidity
variation
10 %/h
Storage humidity
(during transportation
and storage with
packages)
5% RH to 95% RH
Altitude Operating altitude of
disks
l HDDs: -304.8 m to +3048 m (-1000 ft.
to +10000 ft.)
l SSDs: -305 m to +3048 m (-1000.66 ft.
to +10000 ft.)
Non-operating altitude
of disks
l HDDs: -305 m to +12192 m (-1000.66
ft. to +40000 ft.)
l SSDs: -305 m to +12192 m (-1000.66
ft. to +40000 ft.)
a: RH, Relative Humidity
7.2 Vibration and Shock
Vibration and shock requirements must be met so that storage systems can work correctly or
be properly preserved.
Table 7-2 lists the vibration and shock requirements of storage systems.
Table 7-2 Vibration and shock requirements of storage systems
Parameter
Requirement
Operating vibration
5 to 350 Hz, PSD: 0.0002 g
2
/Hz, 350 to 500 Hz, -3 dB, 0.3 Grms,
axial direction: 3 axes
OceanStor 2600 V3
Product Description
7 Environmental Requirements