Product description
DynaMAX 550P/560P/575P Waterjet Pump Operator Manual 811390 43
Hydraulic fluid tank
Boost pump
A minimum supply water pressure is necessary to operate the pump. A boost pump increases the
water pressure to a value higher than the minimum requirement.
When the intensifier starts to stroke, the boost pump turns on. When there is no demand for cutting
water, the boost pump turns off.
Hydraulic fluid filter
This filter removes contamination from the hydraulic fluid.
1
Filler-breather cap
The filler-breather cap keeps airborne
contamination out of the tank and
prevents pressure from building up in the
tank. It also gives access to the tank for
adding hydraulic fluid.
2
Sight gauge
A temperature sensor and a level sensor
in the tank monitor the hydraulic fluid. Use
the sight gauge to see the hydraulic fluid
level and quality.
3
Drain valve
Use the drain valve to drain the tank.
4
Suction strainer
Suction strainers prevent contamination
from entering the primary pump and the
gear pump.