HyPrecision 50S/60S/75S Operator Manual 808690 179
8 – Pump specifications
Pump specifications
HyPrecision 75S
Dimensions and weights
The shipping weight is for the pump, the pallet, and the packaging. Exact weights are taken at shipment.
Operating weight is for an unpackaged pump with hydraulic fluid.
Width 1,016 mm (40 in.) Shipping weight 1,415 kg (3,120 lb)
Length 1,930 mm (76 in.) Operating weight 1,497 kg (3,300 lb)
Height 1,422 mm (56 in.)
56 kW, 75 hp
50 Hz 60 Hz
Voltage 400 V 460 V
Full load current 103.0 A 87.1 A
Primary circuit breaker rating 125.0 A 100.0 A
50 Hz 60 Hz
CUTTING WATER IN Minimum Maximum
Flow
11.4 L/minute
(3 gallons/minute)
—
Pressure
2.76 bar or 275.79 kPa
(40 psi)
7.93 bar or 792.90 kPa
(115 psi)
CUTTING WATER OUT
Flow
—
5.7 L/minute
(1.49 gallons/minute)
6.1 L/minute
(1.60 gallons/minute)
Pressure
551.58 bar or 55,158 kPa
(8,000 psi)
4,136.85 bar or 413,685 kPa
(60,000 psi)
Continuous pressure
—
4,136.85 bar or 413,685 kPa
(60,000 psi)
Cutting water pressure
factory setpoint
—
4,136.85 bar or 413,685 kPa
(60,000 psi)
Piercing water pressure
factory setpoint
1,38.95 bar or 137,895 kPa
(20,000 psi)
—
COOLING IN and COOLING OUT
Flow
11.4 L/minute
(3 gallons/minute)
—
Pressure
2.76 bar or 275.79 kPa
(40 psi)
7.93 bar or 792.90 kPa
(115 psi)