66 HyPrecision 50S/60S/75S Operator Manual 808690
4 – Operation
Operation
Operate the pump remotely
Refer to the remote source manufacturer’s instructions for operating the pump from a remote source.
If the pump is connected to a remote source and is using the remote CONTROLS ON function, refer to the
remote source manufacturer’s instructions for an emergency stop reset.
CONTROLS ON
This turns on the control circuit inside the pump.
The pump can not be turned on until the control circuit is on.
EMERGENCY
STOP
The EMERGENCY STOP button is available on the operation panel and at the remote
control source.
If the pump is running, this turns off the pump. The EMERGENCY STOP button is intended
for urgent disabling of the controls. It is not the preferred method of turning off the pump.
PUMP ON
If the pump is off, this enables the fan motor starter and turns on the primary motor, the
boost pump, and the low-pressure water. When the motor is at operating speed, the
intensifier strokes in pierce-pressure mode for a time that is set at the operator interface.
When the timer expires, the intensifier strokes in cut-pressure mode.
If the pressure control is set to pierce-pressure mode, the pump starts and stays in
pierce-pressure mode.
If the pump is in cooling mode, the intensifier strokes.
PUMP OFF
This turns off the intensifier, the boost pump, the primary motor, the low-pressure water, and
the cooling fan.
In air-cooled systems, it also turns off the fan motor starter and the cooling fan.
It is recommended that the pump not be turned off for stand-by status between programs or
jobs.
COOLING ON
If the pump is running, this turns off the intensifier. The pump runs at the minimum hydraulic
pressure (551.58 bar/8000 psi).
If the pump is off, this turns on the primary motor and the cooling water or the cooling fan.