182 HyPrecision 50S/60S/75S Operator Manual 808690
8 Pump specifications
Pump specifications
Fittings
These charts apply to all hydraulic and high-pressure water fittings. Use a high-pressure antiseize lubricant such
as Blue Goop or AccuGoop on high-pressure water fittings.
Special fittings
Use these values when no other torque value is identified. Other torque specifications are included on the
technical drawings.
Do not use lubricants on low-pressure water fittings.
Wrench size
Torque
N∙m lbfft
Output adapter
1inch 41to47 30to35
High-pressure water fittings (gland nuts)
1/4 inch
5/8inch 20to34 15to25
3/8 inch
13/16 inch 47 to 61 35 to 45
9/16 inch
1-3/16 inch 81 to 102 60 to 75