186 HyPrecision 50S/60S/75S Operator Manual 808690
9 – Installation
Installation
Buyer obligations
Hypertherm does not always ship the pump with hydraulic fluid in the tank. It is the buyer's responsibility to fill
the tank with hydraulic fluid.
The buyer is responsible for these obligations:
Cooperate with Hypertherm and the Hypertherm original equipment manufacturer (OEM) regarding the
installation of the equipment.
Research and comply with all local codes, including requirements for wastewater disposal.
Install high-pressure tubing.
Install water-treatment equipment before the pump is installed.
Make sure that all utilities are available during installation. The site must have sufficient electrical power, air,
water, and sewer drain access.
Make all connections to the pump.
Perform user qualification and training. Refer to User qualification and training on page 20 for more
information.
Seller obligations
If Hypertherm Inc. installs the equipment, some or all of these tasks are the responsibility of the Hypertherm
technician as defined in the sales agreement.
Make sure that the buyer understands all buyer obligations.
Make sure that the site is prepared for installation.
Make sure that all utility connections are correctly routed.
Follow all setup and first-time startup instructions in this manual.
Provide training for maintenance and repair procedures.
Follow standard system acceptance tests.
CAUTION
This pump is capable of generating water pressure of up to 4,137 bar
or 413,685 kPa (60,000 psi). Only use high-pressure tubing that is rated for this pressure.
CAUTION
Support all plumbing to prevent bending stress and fatigue from vibration. A disruption or crack in
plumbing can cause injuries to people or damage to equipment.