84 HyPrecision 50S/60S/75S Operator Manual 808690
5 – Preventive maintenance
Preventive maintenance
Replace the hydraulic fluid, the hydraulic filter, the filler-breather cap, and the
suction strainers
CAUTION
Failure to correct the cause of a leak can cause damage to the water fittings.
Follow local regulations when disposing of used fluids and filters.
Install a new hydraulic filter and filler-breather cap when replacing the hydraulic fluid.
Service Interval
Replace the hydraulic filter After every 1,500 hours of operation
Replace the hydraulic fluid and the suction strainers After every 3,000 hours of operation
1 Filler-breather cap
2 Sight gauge
3 Access cover
4 Drain valve plug and lever
5 Hydraulic filter
6
7
8