Display Hexadecimal Report for Resource
Serial Resource
Name Type Model Number Name
TAP02 3592 J1A 13-10063 DEVICE
Offset 0 1 2 3 4 5 6 7 8 9 A B C D E F EBCDIC
000180 F8807800 65010001 00000270 1700FFFF 8...............
000190 35920J1A 93500001 00631202 05D8D5E6 .....&.......QNW
0001A0 F0F0F5F0 40404250 00009200 00000000 0050 .&........
0001B0 00040000 0000A0B0 0E223444 32440000 ................
0001C0 0000F000 03000000 00400000 00000900 ..0...... ......
0001D0 862A3118 00010003 01300009 42494280 ................
0001E0 10001035 42000133 6B050433 54000000 ........,.......
0001F0 00000003 00000400 00005A90 00000003 ..........!.....
000200 00000100 00002300 00003433 41202020 ................
000210 20001000 00505152 39353000 00000600 ................
000220 00000000 00000000 00000000 00000000 ................
000230 00001000 0003FFFF FFFC1200 0331D9E2 ..............RS
More...
Press Enter to continue.
F3=Exit F12=Cancel
Note: Figure 26 on page 66
provides an example of a typical System i report. Display contents varies by
displacement, depending on the operating system release. If you do not nd either F0, F1, 70, or 71
(locator byte) in Location 1C2, then browse around that area and adjust the displacement accordingly.
Remember that the rst FSC is directly below the located byte. Figure 27 on page 67 depicts a typical
System i (OS/400) system report.
OFFSET HEX ASCII DESCRIPTION
0184-0185 6501 IOP Type
018C-018D 1700 1 = IOP Port Used
700 = Drive Address
0190-0193 35920J1A Device Type and Model
0194-0195 9350 SRC (system reference code)
01C4 03 Sense Key
01CE-01CF 0900 ASC/ASCQ (additional sense code/additional sense code qualifier)
(See “Sense Keys, ASC, and ASCQ information” on page 47
for error sense information.)
01D0 86 FID (FRU identification number)
01D2-01D3 3118 First FSC (fault symptom code)
01E3-01E4 3542 Second FSC (fault symptom code)
01E7-01E8 336B Next to Last FSC (fault symptom code)
01EB-01EC 3354 Last FSC (fault symptom code)
020A-020C 343341 43A Microcode level
0215-021A 505152393530 VOLSER Number in ASCII or EBCDIC
Figure 26: System i hexadecimal Error Log (display)
66
IBM 3592 TS1140, TS1150, TS1155, and TS1160 Tape Drives: Maintenance Information

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM TS1160 and is the answer not in the manual?

IBM TS1160 Specifications

General IconGeneral
BrandIBM
ModelTS1160
CategoryStorage
LanguageEnglish

Related product manuals