X'02
TRANSPORT FAULT - Failure in the transport layer.
X'03
COMMAND TIMEOUT - Command that is timed out before completion. AIX device driver (Atape).
The example shows a failure.
X'04
NO DEVICE RESPONSE - Target did not respond to attempts to select it.
X'05
ADAPTER HARDWARE FAILURE - Adapter indicated a hardware failure.
X'06
ADAPTER SOFTWARE FAILURE - Adapter indicated a microcode failure.
X'07
WW NAME CHANGE - Adapter detected a new worldwide name for the device.
X'08
FUSE OR TERMINAL PWR - Blown terminator fuse or bad termination.
X'09
TRANSPORT RESET - Adapter detected an external SCSI bus reset.
X'0A
TRANSPORT BUSY - The transport layer is busy.
X'0B
TRANSPORT DEAD - The transport layer is inoperative.
ss…
X'00…
DEVICE SENSE DATA - Since the rst byte is not '70,' '71,' 'F0,' or 'F1,' the area that is normally
reserved for device sense data is not valid (and therefore contains zeros). If byte 'gg' indicates a
check condition, the 'ss' byte contains '70,' '71,' 'F0,' or 'F1'. The remaining bytes are valid device
sense data. See the appropriate device reference manual for the specic format and content of
these bytes.
76
IBM 3592 TS1140, TS1150, TS1155, and TS1160 Tape Drives: Maintenance Information

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM TS1160 and is the answer not in the manual?

IBM TS1160 Specifications

General IconGeneral
BrandIBM
ModelTS1160
CategoryStorage
LanguageEnglish

Related product manuals