35
2. ADVANCED OPERATIONS
Tone squelch operation
The Tone squelch opens only when you receive a
signal that includes a matching subaudible tone in the
FM mode. You can silently wait for calls from other
stations using the same tone.
When you transmit, the tone frequency is
superimposed on your own signal.
1. Set the operating frequency in the FM mode.
(Example: 29.550.00 MHz)
2. Touch [TONE] several times to select “TSQL.
L Touching [TONE] changes between “TONE,” “TSQL”
and “OFF.”
3. Touch [TONE] for 1 second.
Selectable tone frequencies
67.0 88.5 114.8 151.4 177.3 203.5 250.3
69.3 91.5 118.8 156.7 179.9 206.5 254.1
71.9 94.8 123.0 159.8 183.5 210.7
74.4 97.4 127.3 162.2 186.2 218.1
77.0 100.0 131.8 165.5 189.9 225.7
79.7 103.5 136.5 167.9 192.8 229.1
82.5 107.2 141.3 171.3 196.6 233.6
85.4 110.9 146.2 173.8 199.5 241.8
Checking another station’s tone frequency

tone scanning while the station is transmitting.
1. Touch [T-SCAN].
The scan starts, and then stops when the tone
frequency as another station is received.
2. To close the TONE FREQUENCY screen, push
EXIT
.
4. Rotate
MAIN
DIAL
to select the tone frequency.
Touch for 1 second to
reset to the default.
Blinks while scanning

Table of Contents

Other manuals for Icom IC-7610

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Icom IC-7610 and is the answer not in the manual?

Icom IC-7610 Specifications

General IconGeneral
BrandIcom
ModelIC-7610
CategoryTransceiver
LanguageEnglish

Related product manuals