Intel
®
Server System P4000CP Thermal Management Intel
®
Server Board S2600CP and Server System P4000CP TPS
Revision 1.1
Intel order number G26942-003
120
Two 120 x 38 mm fans provide cooling for the processors, memory, hard drives and add-in cards.
The two fans draw air
through the rear of each hard drive bay to provide drive, processors, and
memory cooling. All system fans provide a signal for RPM detection the server board can make
available for server management functions.
In addition, the power supply fan provides cooling for the power supply.
Figure 49. Fixed Fans in Intel
®
Server Chassis P4308XXMXXMFEN
12.3.2 Redundant Cooling Solution
Redundant cooling solution is used in the Intel
®
Server Chassis P4308XXMXXMHGC and
P4208XXMHGC.
Five hot-swap 80x38mm fans provide cooling for the processors, hard drives, and add-in cards.
When any single fan fails, the remaining fans increase in speed and maintain cooling until the
failed unit is replaced. All system fans provide a signal for RPM detection that the server board
can make available for server management functions.
In addition, the power supply fan provides cooling for the power supply.
Figure 50. Hot-swap Fans in Intel
®
Server Chassis P4308XXMXXMHGC