Server System P4000CP Power System Options Intel
®
Server Board S2600CP and Server System P4000CP TPS
Revision 1.1
Intel order number G26942-003
140
Table 92. AC Input Voltage Range
Parameter MIN Rated V
MAX
Start up VAC
Power Off
VAC
Voltage (110) 90 V
rms
100-127 V
rms
140 V
rms
85VAC +/-
4VAC
70VAC +/-
5VAC
Voltage (220) 180 V
rms
200-240 V
rms
264 V
rms
Frequency 47 Hz 50/60 63 Hz
Notes:
1. Maximum input current at low input voltage range shall be measured at 90VAC, at max load.
2. Maximum input current at high input voltage range shall be measured at 180VAC, at max load.
3. This requirement is not to be used for determining agency input current markings.
13.3.2.4 AC Line Dropout/Holdup
An AC line dropout is defined to be when the AC input drops to 0VAC at any phase of the AC
line for any length of time. During an AC dropout the power supply meets dynamic voltage
regulation requirements. An AC line dropout of any duration does not cause tripping of control
signals or protection circuits. If the AC dropout lasts longer than the holdup time the power
supply recovers and meets all turn on requirements. The power supply meets the AC dropout
requirement over rated AC voltages and frequencies. A dropout of the AC line for any duration
does not cause damage to the power supply.
Table 93. AC Line Holdup Time
Loading Holdup time
70% 12msec
13.3.2.4.1 AC Line 12VSBHoldup
The 12VSB output voltage stays in regulation under its full load (static or dynamic) during an AC
dropout of 70ms min (=12VSB holdup time) whether the power supply is in ON or OFF state
(PSON asserted or de-asserted).
13.3.2.5 AC Line Fuse
The power supply has one line fused in the single line fuse on the line (Hot) wire of the AC
input. The line fusing is acceptable for all safety agency requirements. The input is a slow blow
type. AC inrush current does not cause the AC line fuse to blow under any conditions. All
protection circuits in the power supply does not cause the AC fuse to blow unless a component
in the power supply has failed. This includes DC output load short conditions.
13.3.2.6 AC Line Transient Specification
AC line transient conditions are defined assag” and “surge” conditions. “Sag” conditions are
also commonly referred to as “brownout”, these conditions is defined as the AC line voltage
dropping below nominal voltage conditions. “Surge” is defined to refer to conditions when the
AC line voltage rises above nominal voltage.
The power supply meets the requirements under the following AC line sag and surge conditions.