Intel
®
Server Board S2600CP and Server System P4000CP TPS Intel® Server System P4000CP Overview
Revision 1.1
Intel order number G26942-003
21
Intel C600 RAID Upgrade Key RKSAS8
Intel
®
Server Chassis P4208XXMXXMHGC includes two 750-W redundant PSU and one 8x2.5"
hot-swap HDD cage allows support for up to eight 2.5" hot-swap SATA/SAS drives. Five
redundant hot-swap fans (80x38mm) at the front edge of the chassis and one air duct for Intel
®
Server Board. Three 5.25-inch half-height peripheral bays are available for the installation of a
floppy drive, CD-ROM drive, and/or other accessories. The standard chassis configuration is
pedestal.
The following table summarizes the Intel
®
Server System P4000CP features:
Table 2. Intel
®
Server System P4000CP family Features
Feature Description
Processors Support for one or two Intel
Xeon
E5-2600 Processor(s)
8 GT/s Intel
®
Quick Path Interconnect (Intel
®
QPI)
LGA 2011 Socket
Thermal Design Power up to 135-W
Memory Eight memory channels (four channels for each processor socket)
Channels A, B, C, D, E, F, G and H
Support for 800/1066/1333/1600 MHz/s Registered DDR3 Memory (RDIMM),
Unbuffered DDR3 memory ((UDIMM) and Load Reduced DDR3 memory (LRDIMM)
DDR3 standard I/O voltage of 1.5V and DDR3 Low Voltage of 1.35V
Refer to chapter 4.2.2 for detail information for memory support.
Chipset Intel
C600 -A chipset with support for Intel
C600 RAID Upgrade Keys
Cooling Fan Support Two processor fans (4-pin headers)
Six front system fans (6-pin headers)
One rear system fan (4-pin header)
Add-in Card Slots Support up to six expansion slots
From first processor:
o Slot 1: PCIe Gen III x4/x8 electrical with x8 physical connector
o Slot 2: PCIe Gen III x8 electrical with x8 physical connector
o Slot 3: PCIe Gen III x8 electrical with x8 open-ended physical connector
o Slot 4: PCIe Gen III x8 electrical with x8 physical connector
o Slot 6: PCIe Gen III x8 electrical with x16 connector, support riser card.
From second processor:
o Slot 5: PCIe Gen III x8 electrical with x8 open-ended physical connector
PCIe slot 5 is functional only when the second processor is installed.
Hard Drive and Optical
Drive Support
Two SATA connectors at 6 Gbps and four SATA connectors at 3 Gbps. The 6 Gbps
connectors are recommended connectors for ODDs.
Up to eight SATA/SAS connectors at 3 Gbps with optional Intel
®
C600 RAID
Upgrade Keys
RAID Support Intel RSTe SW RAID 0/1/10/5
LSI SW RAID 0/1/10
External I/O Connectors One DB-15 video connector
One DB9 serial port A connection
Support two or four 10/100/1000Mb NIC
Four USB 2.0 ports