Intel
®
Server Board S2600CP and Server System P4000CP TPS
Intel® Server Board S2600CP and Intel® Server System P4000CP Platform Management
Revision 1.1
Intel order number G26942-003
77
3. Activating a SOL session requires an existing IPMI-over-LAN session. If encryption is
used, it should be negotiated when the IPMI-over LAN session is established. SOL
sessions are only supported on serial port 1 (COM1).
6.4.3.13 Platform Event Filter (PEF)
The BMC includes the ability to generate a selectable action, such as a system power-off or
reset, when a match occurs to one of a configurable set of events. This capability is called
Platform Event Filtering, or PEF. One of the available PEF actions is to trigger the BMC to send
a LAN alert to one or more destinations.
The BMC supports 20 PEF filters. The first twelve entries in the PEF filter table are pre-
configured (but may be changed by the user). The remaining entries are left blank, and may be
configured by the user.
Table 24. Factory Configured PEF Table Entries
Event Filter
Number
Offset Mask Events
1 Non-critical, critical and non-
recoverable
Temperature sensor out of range
2 Non-critical, critical and non-
recoverable
Voltage sensor out of range
3 Non-critical, critical and non-
recoverable
Fan failure
4 General chassis intrusion Chassis intrusion (security violation)
5 Failure and predictive failure Power supply failure
6 Uncorrectable ECC BIOS
7 POST error BIOS: POST code error
8 FRB2 Watchdog Timer expiration for FRB2
9 Policy Correction Time Node Manager
10 Power down, power cycle, and reset Watchdog timer
11 OEM system boot event System restart (reboot)
12 Drive Failure, Predicted Failure Hot Swap Controller
Additionally, the BMC supports the following PEF actions:
Power off
Power cycle
Reset
OEM action
Alerts
The “Diagnostic interrupt” action is not supported.
6.4.3.14 LAN Alerting
The BMC supports sending embedded LAN alerts, called SNMP PET (Platform Event traps),
and SMTP email alerts.