EasyManuals Logo
Home>Intel>Server Board>S2600CP Family

Intel S2600CP Family User Manual

Intel S2600CP Family
223 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #158 background imageLoading...
Page #158 background image
Intel
®
Server System P4000CP Power System Options Intel
®
Server Board S2600CP and Server System P4000CP TPS
Revision 1.1
Intel order number G26942-003
142
13.3.4.2 Standby Output
The 12VSB output is present when an AC input greater than the power supply turn on voltage is
applied.
13.3.4.3 Voltage Regulation
The power supply output voltages stay within the following voltage limits when operating at
steady state and dynamic loading conditions. These limits include the peak-peak ripple/noise.
These shall be measured at the output connectors.
Table 98. Voltage Regulation Limits
Parameter Tolerance Min Nom Max Units
+12V - 5%/+5% +11.40 +12.00 +12.60 V
rms
+12V stby - 5%/+5% +11.40 +12.00 +12.60 V
rms
13.3.4.4 Dynamic Loading
The output voltages remains within limits specified for the step loading and capacitive loading
specified in the table below. The load transient repetition rate is tested between 50Hz and 5kHz
at duty cycles ranging from 10%-90%. The load transient repetition rate is only a test
specification. The step load may occur anywhere within the MIN load to the MAX
load conditions.
Table 99. Transient Load Requirements
Output Step Load Size
(See note 2)
Load Slew Rate
Test capacitive Load
+12VSB 1.0A
0.25 A/
sec 20
F
+12V 60% of max load
0.25 A/
sec 2000
F
Note:
For dynamic condition +12V min loading is 1A.
13.3.4.5 Capacitive Loading
The power supply is stable and meets all requirements with the following capacitive loading
ranges.
Table 100. Capacitive Loading Conditions
Output Min Max Units
+12VSB 20 3100
F
+12V 500 25000
F
13.3.4.6 Grounding
The output ground of the pins of the power supply provides the output power return path. The
output connector ground pins are connected to the safety ground (power supply enclosure).
This grounding is well designed to ensure passing the max allowed Common Mode Noise levels.
The power supply is provided with a reliable protective earth ground. All secondary circuits is
connected to protective earth ground. Resistance of the ground returns to chassis does not
exceed 1.0 m. This path may be used to carry DC current.